• English
    • Deutsch
    • French
    • Requires WPML plugin
  • Country
    • United States (USD)
    • Deutschland (EUR)
    • Japan (JPY)
  • Newsletter
  • Contact Us
  • FAQs
  • Home
  • All Products
    • Electerical
      • Electerical
        • LV Switchboard
        • LV Motors
        • Lighting System
        • Junction Box
        • Cable Gland
        • Electrical Meters
        • Electrical Cable
        • Battery
        • Current Transformers
        • Circuit Breakers
        • Generators
        • Terminal Block
        • UPS
        • Transformers
        • Plugs and Sockets
        • Relay

      Lorem Ipsum

      Lorem Ipsum is simply dummy text of the printing and typesetting industry. Lorem Ipsum has been the industry's standard dummy text ever since the 1500s, when an unknown printer took a galley

      View More
    • Instrument
      • Instrument
        • LV Switchboard
        • Pressure Instruments
        • SCADA Systems
        • Temperature Instruments
        • PLC
        • Metering Systems
        • Machine Monitoring System
        • Flow Instruments
        • ESD, F&G SYS, DELUGE SYS
        • Distributed Control System
        • analyzers
        • Control & Actuator
    • Mechanical
      • Mechanical
        • Pumps
        • Fan & Blower
        • Steam turbine
        • Combined Cool, Heat and Power (Trigeneration)
        • Filters, Separators , Drains
        • Mixers and agitators
        • CHP
        • Gas turbine
    • Piping
      • Piping
        • pipe
        • valve
        • Flange
        • Fittings
    • Telecom
      • Telecom
        • Non-Directional Beacon (NDB)
        • Fiber Optic Cable
        • PABX Telephone System
        • VHF Radio Communication
        • UHF and Tetra
        • Telecom Systems
        • PAGA System
  • Manufacturers
  • About us
  • Contact us
Login / Register
0 items €0.00
Search
Menu
0 items €0.00
Browse Categories
  • Chemical
    • Beauty & Personal Care
    • Coatings and
    • Construction
    • Energy
    • Food and Nutrition
    • Home care
    • Lubricants
    • Oil & Gas
    • Pharmaceuticals
    • Plastics
    • Water solutions
  • Control, Automation & Instrumentation
    • Actuators
    • Circuit Breakers
    • Connectors
    • Controllers
    • DC Speed Governor
    • Drives
    • Fans
    • HMI touch panel
    • Industrial PC
    • Inverter
    • Low voltage electrical
    • apparatus
    • PLC
    • Powe Supplies
    • Power Supply
    • Relays
    • Remote I/O
    • Sensors
    • Servo
    • Soft starter
    • Soft starter
    • Switches
    • Transmitter
  • Drilling
    • Casing
    • accessories
    • Collars/Stabs
    • Conical picks
    • Drill bits
    • Drill pipes
    • Drill rods
    • DTH hammer
    • Electrical parts
    • Mud/Fluids
    • Pumps
    • Sub Adaptors
  • Mechanical
    • Air compressor
    • parts
    • Bearings
    • Belts and Pulleys
    • Couplings
    • Electrical parts
    • Engine spare parts
    • Hydraulic parts
    • Power transmition
    • Pump parts
    • Seals
    • Springs
  • PC Components and Storages
  • Piping
    • Valves
    • Actuator and
    • accessories
    • Ball valves
    • Butterfly valves
    • Check valves
    • Control valves
    • Diaphragm valves
    • Fittings
    • Flanges
    • Gate valves
    • Globe valves
    • Instrumentation valves
    • Pipes
    • Plates
    • Plug valves
    • Pressure relief valves
    • Safety valves
    • Solenoid valves
    • Steam traps
    • Tubing
    • Y-strainers
  • Process
  • Renewables
    • Charge controllers
    • Gearbox
    • Generator
    • Nacelle
    • Rotor blades
    • Rotor hub
    • Semiconductors
    • Solar accessories
    • Solar batteries
    • Solar battery accessori
    • Solar combiners
    • Solar inverters
    • Solar inverters accesso
    • Solar LED lights
    • Solar panel mounts
    • Solar power panels
    • Tower
  • Process control
    • Flow controllers
    • Flow transmitters
    • Pressure gauges
    • Pressure transmitters
    • Sensors
    • Temperature gauges
    • Temperature transmitt
    • Thermometers
    • Valves
Click to enlarge
Home Automation & Instrumentation SIMENS-6ES7414-2XL07-0AB0
SIMENS-6ES7412-1XJ07-0AB0
SIMENS-6ES7412-1XJ07-0AB0
Back to products
SIMENS-6ES7416-2XP07-0AB0
SIMENS-6ES7416-2XP07-0AB0
SIEMENS

SIMENS-6ES7414-2XL07-0AB0

SIMATIC S7-400, CPU 414-2 Central processing unit with: Work memory 2 MB, (1
MB code, 1 MB data), 1st interface MPI/DP 12 Mbit/s, 2nd interface PROFIBUS
DP,

Compare
Add to wishlist
Category: Automation & Instrumentation
Share:
  • Description
  • Additional information
  • Reviews (0)
  • Shipping & Delivery
Description
CPU-blocks
DB
● Number, max.
● Size, max.
6 000; Number range: 1 to 16000
64 kbyte
FB
● Number, max.
● Size, max.
3 000; Number range: 0 to 7999
64 kbyte
FC
● Number, max.
● Size, max.
3 000; Number range: 0 to 7999
64 kbyte
OB
● Number, max.
● Size, max.
● Number of free cycle OBs
● Number of time alarm OBs
● Number of delay alarm OBs
● Number of cyclic interrupt OBs
● Number of process alarm OBs
● Number of DPV1 alarm OBs
● Number of isochronous mode OBs
● Number of multicomputing OBs
● Number of background OBs
● Number of startup OBs
● Number of asynchronous error OBs
● Number of synchronous error OBs
see instruction list 64 kbyte
1; OB 1
4; OB 10-13
4; OB 20-23
4; OB 32-35 (shortest cycle that can be set = 500 µs) 4; OB 40-43
3; OB 55-57
3; OB 61-63
1; OB 60
1; OB 90
3; OB 100-102
9; OB 80-88
2; OB 121, 122
Nesting depth
● per priority class
● additional within an error OB
24
1
Counters, timers and their retentivity
S7 counter
● Number 2 048
Retentivity
— adjustable
— lower limit
— upper limit
— preset
Yes 0
2 047
Z 0 to Z 7
Counting range
— lower limit
— upper limit
0
999
IEC counter
● present
● Type
● Number
Yes SFB
Unlimited (limited only by RAM capacity)
S7 times
● Number 2 048
Retentivity
— adjustable
— lower limit
— upper limit
— preset
Yes 0
2 047
No times retentive
Time range
— lower limit
— upper limit
10 ms
9 990 s
IEC timer
● present
● Type
● Number
Yes SFB
Unlimited (limited only by RAM capacity)
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. Total working and load memory (with backup battery)
Flag
● Size, max.
● Retentivity available
● Retentivity preset
● Number of clock memories
8 kbyte; Size of bit memory address area Yes
MB 0 to MB 15
8; in 1 memory byte
Local data
● adjustable, max.
● preset
16 kbyte
8 kbyte
Address area
I/O address area
● Inputs
● Outputs
8 kbyte
8 kbyte
Process image
● Inputs, adjustable
● Outputs, adjustable
● Inputs, default
● Outputs, default
● consistent data, max.
● Access to consistent data in process image
8 kbyte
8 kbyte
256 byte
256 byte
244 byte Yes
Subprocess images
● Number of subprocess images, max. 15
Digital channels
● Inputs
— of which central
● Outputs
— of which central
65 536
65 536
65 536
65 536
Analog channels
● Inputs
— of which central
● Outputs
— of which central
4 096
4 096
4 096
4 096
Hardware configuration
Number of expansion units, max. 21
63
Yes; 4 CPUs max. (with UR1 or UR2)
connectable OPs
Multicomputing
Interface modules
● Number of connectable IMs (total), max.
● Number of connectable IM 460s, max.
● Number of connectable IM 463s, max.
6
6
4; IM 463-2
Number of DP masters
● integrated
● via CP
● via IM 467
● Mixed mode IM + CP permitted
● via interface module
● Number of pluggable S5 modules (via adapter capsule in central device), max.
2
10; CP 443-5 Extended
4
No; IM 467 cannot be used jointly with CP 443-5 Ext. or CP 443-1 in PROFINET IO mode
0
6
Number of IO Controllers
● integrated
● via CP
0
4; Max. 4 in the central controller; no mixed operation of different CP 443-1 types in PROFINET IO mode
Number of operable FMs and CPs (recommended)
● FM
● CP, PtP
● PROFIBUS and Ethernet CPs
Limited by number of slots and number of connections
CP 440: Limited by number of slots; CP 441: limited by number of connections
14; In total max. 10 CPs as DP master and PROFINET controller, of which up to 10 IMs or CPs as DP master and up to 4 CPs as PROFINET controller
Slots
● required slots 1
Time of day
Clock
● Hardware clock (real-time)
● retentive and synchronizable
● Resolution
● Deviation per day (buffered), max.
● Deviation per day (unbuffered), max.
Yes

Yes 1 ms
1.7 s; Power off
8.6 s; For power On

Operating hours counter
● Number
● Number/Number range
● Range of values
● Granularity
● retentive
16
0 to 15
SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 – 1 hours
1 h Yes
Clock synchronization
● supported
● to MPI, master
● to MPI, slave
● to DP, master
● to DP, slave
● in AS, master
● in AS, slave
● on Ethernet via NTP
● to IF 964 DP
Yes

Yes

Yes

Yes

Yes

Yes

Yes
No; Via CP
No

Time difference in system when synchronizing via
● MPI, max. 200 ms
Interfaces
Interfaces/bus type 1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP
2; Combined MPI / PROFIBUS DP and PROFIBUS DP
Number of RS 485 interfaces
1. Interface
Interface type MPI/PROFIBUS DP
Yes
Isolated
Interface types
● RS 485
● Output current of the interface, max.
Yes 150 mA
Protocols
● MPI
● PROFIBUS DP master
● PROFIBUS DP slave
Yes
YesYes
MPI
● Number of connections
● Transmission rate, max.
32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
12 Mbit/s
Services
— PG/OP communication
— Routing
— Global data communication
— S7 basic communication
— S7 communication
— S7 communication, as client
— S7 communication, as server
Yes

Yes

Yes

Yes

Yes

Yes
Yes

PROFIBUS DP master
● Number of connections, max.
● Transmission rate, max.
● Number of DP slaves, max.
16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
12 Mbit/s
32
Services
— PG/OP communication
— Routing
— Global data communication
— S7 basic communication
— S7 communication
— S7 communication, as client
— S7 communication, as server
— Equidistance
— Isochronous mode
— SYNC/FREEZE
— Activation/deactivation of DP slaves
— Direct data exchange (slave-to-slave communication)
— DPV1
Yes
Yes; S7 routing No
YesYes

Yes

Yes

Yes

Yes

Yes

Yes

Yes
Yes

Address area
— Inputs, max.
— Outputs, max.
2 kbyte
2 kbyte
User data per DP slave
— User data per DP slave, max.
— Inputs, max.
— Outputs, max.
— Slots, max.
— per slot, max.
244 byte
244 byte
244 byte
244
128 byte
PROFIBUS DP slave
● Number of connections
● GSD file
● Transmission rate, max.
● automatic baud rate search
● Address area, max.
● User data per address area, max.
— of which consistent, max.
16
http://support.automation.siemens.com/WW/view/en/113652 12 Mbit/s
No
32; Virtual slots
32 byte
32 byte
Services
— PG/OP communication
— Routing
— Global data communication
— S7 basic communication
— S7 communication
— S7 communication, as client
— S7 communication, as server
— Direct data exchange (slave-to-slave communication)
— DPV1
Yes; with interface active Yes; with interface active No
No Yes Yes Yes No
No
Transfer memory
— Inputs
— Outputs
244 byte
244 byte
2. Interface
Interface type PROFIBUS DP
Yes 16
Isolated
Number of connection resources
Interface types
● RS 485
● Output current of the interface, max.
Yes 150 mA
Protocols
● PROFIBUS DP master
● PROFIBUS DP slave
Yes

Yes

PROFIBUS DP master
● Number of connections, max.
● Transmission rate, max.
● Number of DP slaves, max.
16
12 Mbit/s
96
Services
— PG/OP communication
— Routing
— Global data communication
— S7 basic communication
— S7 communication
— S7 communication, as client
— S7 communication, as server
— Equidistance
— Isochronous mode
— SYNC/FREEZE
— Activation/deactivation of DP slaves
— Direct data exchange (slave-to-slave communication)
— DPV1
Yes
Yes; S7 routing No
YesYes

Yes

Yes

Yes

Yes

Yes

Yes

Yes
Yes

Address area
— Inputs, max.
— Outputs, max.
6 kbyte
6 kbyte
User data per DP slave
— User data per DP slave, max.
— Inputs, max.
— Outputs, max.
— Slots, max.
— per slot, max.
244 byte
244 byte
244 byte
244
128 byte
PROFIBUS DP slave
● Number of connections
● GSD file
● Transmission rate, max.
● Address area, max.
● User data per address area, max.
— of which consistent, max.
16
http://support.automation.siemens.com/WW/view/en/113652 12 Mbit/s
32
32 byte
32 byte
Services
— Routing Yes; with interface active
Transfer memory
— Inputs
— Outputs
244 byte
244 byte
Protocols
SIMATIC communication
● S7 routing Yes
Open IE communication
● ISO-on-TCP (RFC1006)
— Data length, max.
Via CP 443-1 and loadable FB 1 452 bytes via CP 443-1 Adv.
Web server
● supported No
Isochronous mode
Equidistance Yes 2
244 byte
1 ms; 0.5 ms without use of SFC 126, 127
32 ms
Number of DP masters with isochronous mode
User data per isochronous slave, max.
shortest clock pulse
max. cycle
communication functions / header
PG/OP communication
● Number of connectable OPs without message processing
● Number of connectable OPs with message processing
Yes 63
63; When using Alarm_S/SQ and Alarm_D/DQ
Yes
Data record routing
Global data communication
● supported
● Number of GD loops, max.
● Number of GD packets, transmitter, max.
● Number of GD packets, receiver, max.
● Size of GD packets, max.
● Size of GD packet (of which consistent), max.
Yes 8
8
16
54 byte
1 variable
S7 basic communication
● supported
● User data per job, max.
● User data per job (of which consistent), max.
Yes
76 byte
1 variable
S7 communication
● supported
● as server
● as client
● User data per job, max.
● User data per job (of which consistent), max.
Yes Yes Yes
64 kbyte
462 byte; 1 variable
S5 compatible communication
● supported
● User data per job, max.
● User data per job (of which consistent), max.
● Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.
Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 8 kbyte
240 byte 24/24
Standard communication (FMS)
● supported Yes; Via CP and loadable FB
Number of connections
● overall
● usable for PG communication
— reserved for PG communication
— adjustable for PG communication, max.
● usable for OP communication
— reserved for OP communication
— adjustable for OP communication, max.
● usable for S7 basic communication
— reserved for S7 basic communication
— adjustable for S7 basic communication, max.
● usable for S7 communication
— reserved for S7 communication
— adjustable for S7 communication, max.
● usable for routing
— reserved for routing
— adjustable for routing, max.
64
63
1
0
63
1
0
62
0
0
62
0
0
31
0
0
S7 message functions
Number of login stations for message functions, max. 63; Max. 63 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC)
Yes Yes Yes Yes
400; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks Yes
1 200
300
Yes 16
Symbol-related messages
SCAN procedure
Program alarms
Process diagnostic messages
simultaneously active Alarm-S blocks, max.
Alarm 8-blocks
● Number of instances for alarm 8 and S7 communication blocks, max.
● preset, max.
Process control messages
Number of archives that can log on simultaneously (SFB 37 AR_SEND)
Number of messages
● overall, max.
● in 100 ms grid, max.
● in 500 ms grid, max.
● in 1000 ms grid, max.
512
128
256
512
Number of additional values
● with 100 ms grid, max.
● with 500, 1000 ms grid, max.
1
10
Test commissioning functions
Status block Yes; Up to 16 simultaneously Yes
16
Single step
Number of breakpoints
Status/control
● Status/control variable
● Variables
● Number of variables, max.
Yes; Up to 16 variable tables
Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters 70; Status/control
Forcing
● Forcing
● Forcing, variables
● Number of variables, max.
Yes
Inputs, outputs, bit memories, peripheral inputs, peripheral outputs 256
Diagnostic buffer
● present Yes
● Number of entries, max. 3 200
— adjustable Yes
— preset 120
Service data
● can be read out Yes
Standards, approvals, certificates
CE mark Yes

Yes

Yes

Yes

Yes

Yes

Yes
Yes

CSA approval
UL approval
cULus
FM approval
RCM (formerly C-TICK)
KC approval
EAC (formerly Gost-R)
Use in hazardous areas
● ATEX ATEX II 3G Ex nA IIC T4 Gc
Ambient conditions
Ambient temperature during operation
● min. 0 °C
● max. 60 °C
configuration / header
Configuration software
● STEP 7 Yes
configuration / programming / header
● Command set see instruction list
● Nesting levels 7
● Access to consistent data in process image Yes
● System functions (SFC) see instruction list
● System function blocks (SFB) see instruction list
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— CFC Yes
— GRAPH Yes
— HiGraph® Yes
configuration / programming / number of simultaneously active SFC / header
— number of simultaneously active system functions (SFC) / with DPSYC_FR 2; SFC 11; per interface
— number of simultaneously active system functions (SFC) / with D_ACT_DP 8; SFC 12; per interface
— RD_REC 8; SFC 59; per interface
— WR_REC 8; SFC 58; per interface
— WR_PARM 8; SFC 55; per interface
— PARM_MOD 1; SFC 57; per interface
— WR_DPARM 2; SFC 56; per interface
— DPNRM_DG 8; SFC 13; per interface
— RDSYSST 8; SFC 51
— DP_TOPOL 1; SFC 103; per interface
configuration / programming / number of simultaneously active SFB / header
— RDREC
— WRREC
8; SFB 52; per interface, but not more than 32 across all external interfaces
8; SFB 53; per interface, but not more than 32 across all external interfaces
Know-how protection
● User program protection/password protection
● Block encryption
Yes
Yes; With S7 block Privacy
Dimensions
Width 25 mm
290 mm
219 mm
Height
Depth
Weights
Weight, approx. 700 g

 

Additional information
Dimensions 25 × 290 × 219 cm
Product type designation

CPU 414-2

Power loss, max

5.5 W

Type of memory

RAM

Backup / present

yes

HW functional status

01

Firmware version

V7.0

Isochronous mode

Yes; For PROFIBUS only

Programming package

STEP 7 V5.4 or higher with HSP 261

CiR - Configuration in RUN

CiR synchronization time, basic load 100 ms CiR synchronization time, time per I/O byte 15 µs

Input current

from backplane bus 5 V DC, typ. 0.9 A from backplane bus 5 V DC, max. 1.1 A from backplane bus 24 V DC, max. 300 mA; 150 mA per DP interface from interface 5 V DC, max. 90 mA; At each DP interface

Power loss, typ

4.5 W

Work memory

● integrated 2 Mbyte ● integrated (for program) 1 Mbyte ● integrated (for data) 1 Mbyte ● expandable No

Load memory

● expandable FEPROM Yes; with Memory Card (FLASH) ● expandable FEPROM, max. 64 Mbyte ● integrated RAM, max. 512 kbyte ● expandable RAM Yes; with Memory Card (RAM) ● expandable RAM, max. 64 Mbyte

Backup / without battery

NO

Brand

SIEMENS

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “SIMENS-6ES7414-2XL07-0AB0” Cancel reply

Your email address will not be published. Required fields are marked *

Shipping & Delivery

Related products

Compare

SIMENS-6ES7332-5HF00-0AB0

Automation & Instrumentation
SIMATIC S7-300, Analog output SM 332, isolated, 8 AO, U/I; diagnostics; resolution 11/12 bits, 40-pole, removing and inserting possible with active backplane bus
Add to wishlist
Read more
Quick view
Compare

SIMENS-6ES7288-1ST60-0AA0

Automation & Instrumentation
*** spare part *** SIMATIC S7-200 SMART, CPU ST60, CPU, DC/DC/DC, onboard I/O: 36 DI 24 V DC; 24 DO 24 V DC; power supply: DC 20.4-28.8V DC, program/data memory 50 KB
Add to wishlist
Read more
Quick view
Compare

SIMENS-6ES7288-1SR20-0AA0

Automation & Instrumentation
** spare part *** SIMATIC S7-200 SMART, CPU SR20, CPU, AC/DC/relay, onboard I/O: 12 DI 24 V DC; 8 DO relay 2A; power supply: AC 85-264 V AC at 47- 63 Hz, program/data memory 20 KB
Add to wishlist
Read more
Quick view
Compare

SIMENS-6ES7322-1BH10-0AA0

Automation & Instrumentation
SIMATIC S7-300, Digital output SM 322 High Speed, isolated, 16 DO, 24 V DC, 0.5A, 1x 20-pole
Add to wishlist
Read more
Quick view
Compare

SIMENS-6ES7288-1CR40-0AA0

Automation & Instrumentation
SIMATIC S7-200 SMART, CPU CR40, compact CPU, AC/DC/relay, onboard I/O: 24 DI 24 V DC; 16 DO relay 2A; Power supply: AC 85-264 V AC at 47-63 Hz, Program/data memory 20 KB
Add to wishlist
Read more
Quick view
Compare

SIMENS-6ES7331-1KF02-0AB0

Automation & Instrumentation
SIMATIC S7-300, Analog input SM 331, Isolated 8 AI, resolution 13 bits U/I/resistor/Pt100, NI100, NI1000, LG-NI1000, PTC/KTY, 66 ms conversion time; 1x 40-pole
Add to wishlist
Read more
Quick view
Compare

SIEMENS- 6ES7212-1AE40-0XB0

Automation & Instrumentation
SIMATIC S7-1200, CPU 1212C, compact CPU, DC/DC/DC, onboard I/O: 8 DI 24 V DC; 6 DO 24 V DC; 2 AI 0-10 V DC, Power supply: DC 20.4-28.8V DC, Program/data memory 75 KB
Add to wishlist
Read more
Quick view
Compare

SIMENS-6ES7321-1BH50-0AA0

Automation & Instrumentation
SIMATIC S7-300, Digital input SM 321, Isolated 16 DI, 24 V DC, Source input, 1x 20-pole
Add to wishlist
Read more
Quick view

We are a digital marketplace to facilitate communication between suppliers/manufacturers and buyers.

  • Address: Largo Do Sol Posto, nº 1, 8000-150, Faro, Portugal
  • Email: info@tidasourcing.com
  • Support Emai: support@tidasourcing.com
Recent Posts
Useful Links
  • Stock Material
  • Learning Hub
  • Contact
  • Profile
All rights reserved by TIDASOURCING 2023.
payments
  • Menu
  • Categories
  • Chemical
    • Beauty & Personal Care
    • Coatings and
    • Construction
    • Energy
    • Food and Nutrition
    • Home care
    • Lubricants
    • Oil & Gas
    • Pharmaceuticals
    • Plastics
    • Water solutions
  • Control, Automation & Instrumentation
    • Actuators
    • Circuit Breakers
    • Connectors
    • Controllers
    • DC Speed Governor
    • Drives
    • Fans
    • HMI touch panel
    • Industrial PC
    • Inverter
    • Low voltage electrical
    • apparatus
    • PLC
    • Powe Supplies
    • Power Supply
    • Relays
    • Remote I/O
    • Sensors
    • Servo
    • Soft starter
    • Soft starter
    • Switches
    • Transmitter
  • Drilling
    • Casing
    • accessories
    • Collars/Stabs
    • Conical picks
    • Drill bits
    • Drill pipes
    • Drill rods
    • DTH hammer
    • Electrical parts
    • Mud/Fluids
    • Pumps
    • Sub Adaptors
  • Mechanical
    • Air compressor
    • parts
    • Bearings
    • Belts and Pulleys
    • Couplings
    • Electrical parts
    • Engine spare parts
    • Hydraulic parts
    • Power transmition
    • Pump parts
    • Seals
    • Springs
  • PC Components and Storages
  • Piping
    • Valves
    • Actuator and
    • accessories
    • Ball valves
    • Butterfly valves
    • Check valves
    • Control valves
    • Diaphragm valves
    • Fittings
    • Flanges
    • Gate valves
    • Globe valves
    • Instrumentation valves
    • Pipes
    • Plates
    • Plug valves
    • Pressure relief valves
    • Safety valves
    • Solenoid valves
    • Steam traps
    • Tubing
    • Y-strainers
  • Process
  • Renewables
    • Charge controllers
    • Gearbox
    • Generator
    • Nacelle
    • Rotor blades
    • Rotor hub
    • Semiconductors
    • Solar accessories
    • Solar batteries
    • Solar battery accessori
    • Solar combiners
    • Solar inverters
    • Solar inverters accesso
    • Solar LED lights
    • Solar panel mounts
    • Solar power panels
    • Tower
  • Process control
    • Flow controllers
    • Flow transmitters
    • Pressure gauges
    • Pressure transmitters
    • Sensors
    • Temperature gauges
    • Temperature transmitt
    • Thermometers
    • Valves
  • Home
  • All Products
    • Electerical
    • Instrument
    • Mechanical
    • Piping
    • Telecom
  • Manufacturers
  • About us
  • Contact us
  • Wishlist
  • Compare
  • Login / Register
Shopping cart
Close
Sign in
Close

Lost your password?

No account yet?

Create an Account
Shop
Wishlist
0 items Cart
My account