Battery | |||||||
Backup battery | |||||||
● Backup current, typ. ● Backup current, max. ● Backup time, max. ● Feeding of external backup voltage to CPU |
180 µA; up to 40 °C 850 µA Dealt with in the module data manual with the secondary conditions and the factors of influence 5 V DC to 15 V DC |
||||||
CPU processing times | |||||||
for bit operations, typ. | 12.5 ns 12.5 ns 12.5 ns 25 ns |
||||||
for word operations, typ. | |||||||
for fixed point arithmetic, typ. | |||||||
for floating point arithmetic, typ. | |||||||
CPU-blocks | |||||||
DB | |||||||
● Number, max. ● Size, max. |
10 000; Number range: 1 to 16000 64 kbyte |
||||||
FB | |||||||
● Number, max. ● Size, max. |
5 000; Number range: 0 to 7999 64 kbyte |
||||||
FC | |||||||
● Number, max. ● Size, max. |
5 000; Number range: 0 to 7999 64 kbyte |
||||||
OB | |||||||
● Number, max. ● Size, max. ● Number of free cycle OBs ● Number of time alarm OBs ● Number of delay alarm OBs ● Number of cyclic interrupt OBs ● Number of process alarm OBs ● Number of DPV1 alarm OBs ● Number of isochronous mode OBs ● Number of multicomputing OBs ● Number of background OBs ● Number of startup OBs ● Number of asynchronous error OBs ● Number of synchronous error OBs |
see instruction list 64 kbyte 1; OB 1 8; OB 10-17 4; OB 20-23 9; OB 30-38 (shortest cycle that can be set = 500 µs) 8; OB 40-47 3; OB 55-57 4; OB 61-64 1; OB 60 1; OB 90 3; OB 100-102 9; OB 80-88 2; OB 121, 122 |
||||||
Nesting depth | |||||||
● per priority class ● additional within an error OB |
24 2 |
||||||
Counters, timers and their retentivity | |||||||
S7 counter | |||||||
● Number | 2 048 | ||||||
Retentivity | |||||||
— adjustable — lower limit — upper limit — preset |
Yes 0 2 047 Z 0 to Z 7 |
||||||
Counting range | |||||||
— lower limit — upper limit |
0 999 |
||||||
IEC counter | |||||||
● present ● Type ● Number |
Yes SFB Unlimited (limited only by RAM capacity) |
||||||
S7 times | |||||||
● Number | 2 048 | ||||||
Retentivity | |||||||
— adjustable — lower limit — upper limit — preset |
Yes 0 2 047 No times retentive |
||||||
Time range | |||||||
— lower limit — upper limit |
10 ms 9 990 s |
||||||
IEC timer | |||||||
● present ● Type ● Number |
Yes SFB Unlimited (limited only by RAM capacity) |
||||||
Data areas and their retentivity | |||||||
Retentive data area (incl. timers, counters, flags), max. | Total working and load memory (with backup battery) | ||||||
Flag | |||||||
● Size, max. ● Retentivity available ● Retentivity preset ● Number of clock memories |
16 kbyte; Size of bit memory address area Yes MB 0 to MB 15 8; in 1 memory byte |
||||||
Local data | |||||||
● adjustable, max. ● preset |
32 kbyte 16 kbyte |
||||||
Address area | |||||||
I/O address area | |||||||
● Inputs ● Outputs |
16 kbyte 16 kbyte |
||||||
Process image | |||||||
● Inputs, adjustable ● Outputs, adjustable ● Inputs, default ● Outputs, default ● consistent data, max. ● Access to consistent data in process image |
16 kbyte 16 kbyte 512 byte 512 byte 244 byte Yes |
||||||
Subprocess images | |||||||
● Number of subprocess images, max. | 15 | ||||||
Digital channels | |||||||
● Inputs — of which central ● Outputs — of which central |
131 072 131 072 131 072 131 072 |
||||||
Analog channels | |||||||
● Inputs — of which central ● Outputs — of which central |
8 192 8 192 8 192 8 192 |
||||||
Hardware configuration | |||||||
Number of expansion units, max. | 21 95 Yes; 4 CPUs max. (with UR1 or UR2) |
||||||
connectable OPs | |||||||
Multicomputing | |||||||
Interface modules | |||||||
● Number of connectable IMs (total), max. ● Number of connectable IM 460s, max. ● Number of connectable IM 463s, max. |
6 6 4; IM 463-2 |
||||||
Number of DP masters | |||||||
● integrated ● via CP ● via IM 467 ● Mixed mode IM + CP permitted ● via interface module ● Number of pluggable S5 modules (via adapter capsule in central device), max. |
2 10; CP 443-5 Extended 4 No; IM 467 cannot be used jointly with CP 443-5 Ext. or CP 443-1 in PROFINET IO mode 0 6 |
||||||
Number of IO Controllers | |||||||
● integrated ● via CP |
0 4; Max. 4 in the central controller; no mixed operation of different CP 443-1 types in PROFINET IO mode |
||||||
Number of operable FMs and CPs (recommended) | |||||||
● FM ● CP, PtP ● PROFIBUS and Ethernet CPs |
Limited by number of slots and number of connections CP 440: Limited by number of slots; CP 441: limited by number of connections 14; In total max. 10 CPs as DP master and PROFINET controller, of which up to 10 IMs or CPs as DP master and up to 4 CPs as PROFINET controller |
||||||
Slots | |||||||
● required slots | 1 | ||||||
Time of day | |||||||
Clock | |||||||
● Hardware clock (real-time) ● retentive and synchronizable ● Resolution ● Deviation per day (buffered), max. ● Deviation per day (unbuffered), max. |
Yes Yes 1 ms 1.7 s; Power off 8.6 s; For power On |
||||||
Operating hours counter | |||||||
● Number ● Number/Number range ● Range of values ● Granularity ● retentive |
16 0 to 15 SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 – 1 hours 1 h Yes |
||||||
Clock synchronization | |||||||
● supported ● to MPI, master ● to MPI, slave ● to DP, master ● to DP, slave ● in AS, master ● in AS, slave ● on Ethernet via NTP ● to IF 964 DP |
Yes
Yes Yes Yes Yes Yes Yes |
||||||
Time difference in system when synchronizing via | |||||||
● MPI, max. | 200 ms | ||||||
Interfaces | |||||||
Interfaces/bus type | 1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP 2; Combined MPI / PROFIBUS DP and PROFIBUS DP |
||||||
Number of RS 485 interfaces | |||||||
1. Interface | |||||||
Interface type | MPI/PROFIBUS DP Yes |
||||||
Isolated | |||||||
Interface types | |||||||
● RS 485 ● Output current of the interface, max. |
Yes 150 mA | ||||||
Protocols | |||||||
● MPI ● PROFIBUS DP master ● PROFIBUS DP slave |
Yes Yes Yes |
||||||
MPI | |||||||
● Number of connections ● Transmission rate, max. |
44; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 12 Mbit/s |
||||||
Services | |||||||
— PG/OP communication — Routing — Global data communication — S7 basic communication — S7 communication — S7 communication, as client — S7 communication, as server |
Yes Yes Yes Yes Yes Yes Yes |
||||||
PROFIBUS DP master | |||||||
● Number of connections, max. ● Transmission rate, max. ● Number of DP slaves, max. |
32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 12 Mbit/s 32 |
||||||
Services | |||||||
— PG/OP communication — Routing — Global data communication — S7 basic communication — S7 communication — S7 communication, as client — S7 communication, as server — Equidistance — Isochronous mode — SYNC/FREEZE — Activation/deactivation of DP slaves — Direct data exchange (slave-to-slave communication) — DPV1 |
Yes Yes; S7 routing No YesYes Yes Yes Yes Yes Yes Yes Yes |
||||||
Address area | |||||||
— Inputs, max. — Outputs, max. |
2 kbyte 2 kbyte |
||||||
User data per DP slave | |||||||
— User data per DP slave, max. — Inputs, max. — Outputs, max. — Slots, max. — per slot, max. |
244 byte 244 byte 244 byte 244 128 byte |
||||||
PROFIBUS DP slave | |||||||
● Number of connections ● GSD file ● Transmission rate, max. ● automatic baud rate search ● Address area, max. ● User data per address area, max. — of which consistent, max. |
32 http://support.automation.siemens.com/WW/view/en/113652 12 Mbit/s No 32; Virtual slots 32 byte 32 byte |
||||||
Services | |||||||
— PG/OP communication — Routing — Global data communication — S7 basic communication — S7 communication — S7 communication, as client — S7 communication, as server — Direct data exchange (slave-to-slave communication) — DPV1 |
Yes; with interface active Yes; with interface active No NoYes Yes Yes No |
||||||
Transfer memory | |||||||
— Inputs — Outputs |
244 byte 244 byte |
||||||
2. Interface | |||||||
Interface type | PROFIBUS DP Yes 32 |
||||||
Isolated | |||||||
Number of connection resources | |||||||
Interface types | |||||||
● RS 485 ● Output current of the interface, max. |
Yes 150 mA | ||||||
Protocols | |||||||
● PROFIBUS DP master ● PROFIBUS DP slave |
Yes
Yes |
||||||
PROFIBUS DP master | |||||||
● Number of connections, max. ● Transmission rate, max. ● Number of DP slaves, max. |
32 12 Mbit/s 125 |
||||||
Services | |||||||
— PG/OP communication — Routing — Global data communication — S7 basic communication — S7 communication — S7 communication, as client — S7 communication, as server — Equidistance — Isochronous mode — SYNC/FREEZE — Activation/deactivation of DP slaves — Direct data exchange (slave-to-slave communication) — DPV1 |
Yes Yes; S7 routing No YesYes Yes Yes Yes Yes Yes Yes Yes |
||||||
Address area | |||||||
— Inputs, max. — Outputs, max. |
8 kbyte 8 kbyte |
||||||
User data per DP slave | |||||||
— User data per DP slave, max. — Inputs, max. — Outputs, max. — Slots, max. — per slot, max. |
244 byte 244 byte 244 byte 244 128 byte |
||||||
PROFIBUS DP slave | |||||||
● Number of connections ● GSD file ● Transmission rate, max. ● Address area, max. ● User data per address area, max. — of which consistent, max. |
32 http://support.automation.siemens.com/WW/view/en/113652 12 Mbit/s 32 32 byte 32 byte |
||||||
Services | |||||||
— Routing | Yes; with interface active | ||||||
Transfer memory | |||||||
— Inputs — Outputs |
244 byte 244 byte |
||||||
Protocols | |||||||
SIMATIC communication | |||||||
● S7 routing | Yes | ||||||
Open IE communication | |||||||
● ISO-on-TCP (RFC1006) — Data length, max. |
Via CP 443-1 and loadable FB 1 452 bytes via CP 443-1 Adv. | ||||||
Web server | |||||||
● supported | No | ||||||
Isochronous mode | |||||||
Equidistance | Yes 2 244 byte 1 ms; 0.5 ms without use of SFC 126, 127 32 ms |
||||||
Number of DP masters with isochronous mode | |||||||
User data per isochronous slave, max. | |||||||
shortest clock pulse | |||||||
max. cycle | |||||||
communication functions / header | |||||||
PG/OP communication ● Number of connectable OPs without message processing ● Number of connectable OPs with message processing |
Yes 95 95; When using Alarm_S/SQ and Alarm_D/DQ Yes |
||||||
Data record routing | |||||||
Global data communication | |||||||
● supported ● Number of GD loops, max. ● Number of GD packets, transmitter, max. ● Number of GD packets, receiver, max. ● Size of GD packets, max. ● Size of GD packet (of which consistent), max. |
Yes 16 16 32 54 byte 1 variable |
||||||
S7 basic communication | |||||||
● supported ● User data per job, max. ● User data per job (of which consistent), max. |
Yes 76 byte 1 variable |
||||||
S7 communication | |||||||
● supported ● as server ● as client ● User data per job, max. ● User data per job (of which consistent), max. |
Yes Yes Yes 64 kbyte 462 byte; 1 variable |
||||||
S5 compatible communication | |||||||
● supported ● User data per job, max. ● User data per job (of which consistent), max. ● Number of simultaneous AG-SEND/AG-RECV orders per CPU, max. |
Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 8 kbyte 240 byte 64/64 |
||||||
Standard communication (FMS) | |||||||
● supported | Yes; Via CP and loadable FB | ||||||
Number of connections | |||||||
● overall ● usable for PG communication — reserved for PG communication — adjustable for PG communication, max. ● usable for OP communication — reserved for OP communication — adjustable for OP communication, max. ● usable for S7 basic communication — reserved for S7 basic communication — adjustable for S7 basic communication, max. ● usable for S7 communication — reserved for S7 communication — adjustable for S7 communication, max. ● usable for routing — reserved for routing — adjustable for routing, max. |
96 95 1 0 95 1 0 94 0 0 94 0 0 47 0 0 |
||||||
S7 message functions | |||||||
Number of login stations for message functions, max. | 95; Max. 95 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 16 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC) Yes Yes Yes Yes 1 000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks Yes 4 000 600 Yes 32 |
||||||
Symbol-related messages | |||||||
SCAN procedure | |||||||
Program alarms | |||||||
Process diagnostic messages | |||||||
simultaneously active Alarm-S blocks, max. | |||||||
Alarm 8-blocks ● Number of instances for alarm 8 and S7 communication blocks, max. ● preset, max. |
|||||||
Process control messages | |||||||
Number of archives that can log on simultaneously (SFB 37 AR_SEND) | |||||||
Number of messages | |||||||
● overall, max. ● in 100 ms grid, max. ● in 500 ms grid, max. ● in 1000 ms grid, max. |
1 024 128 512 1 024 |
||||||
Number of additional values | |||||||
● with 100 ms grid, max. ● with 500, 1000 ms grid, max. |
1 10 |
||||||
Test commissioning functions | |||||||
Status block | Yes; Up to 16 simultaneously Yes 16 |
||||||
Single step | |||||||
Number of breakpoints | |||||||
Status/control | |||||||
● Status/control variable ● Variables ● Number of variables, max. |
Yes; Up to 16 variable tables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters 70; Status/control |
||||||
Forcing | |||||||
● Forcing ● Forcing, variables ● Number of variables, max. |
Yes Inputs, outputs, bit memories, peripheral inputs, peripheral outputs 512 |
||||||
Diagnostic buffer | |||||||
● present | Yes | ||||||
● Number of entries, max. | 3 200 | ||||||
— adjustable | Yes | ||||||
— preset | 120 | ||||||
Service data | |||||||
● can be read out | Yes | ||||||
Standards, approvals, certificates | |||||||
CE mark | Yes
Yes Yes Yes Yes Yes Yes |
||||||
CSA approval | |||||||
UL approval | |||||||
cULus | |||||||
FM approval | |||||||
RCM (formerly C-TICK) | |||||||
KC approval | |||||||
EAC (formerly Gost-R) | |||||||
Use in hazardous areas | |||||||
● ATEX | ATEX II 3G Ex nA IIC T4 Gc | ||||||
Ambient conditions | |||||||
Ambient temperature during operation | |||||||
● min. | 0 °C | ||||||
● max. | 60 °C | ||||||
configuration / header | |||||||
Configuration software | |||||||
● STEP 7 | Yes | ||||||
configuration / programming / header | |||||||
● Command set | see instruction list | ||||||
● Nesting levels | 7 | ||||||
● Access to consistent data in process image | Yes | ||||||
● System functions (SFC) | see instruction list | ||||||
● System function blocks (SFB) | see instruction list | ||||||
Programming language | |||||||
— LAD | Yes | ||||||
— FBD | Yes | ||||||
— STL | Yes | ||||||
— SCL | Yes | ||||||
— CFC | Yes | ||||||
— GRAPH | Yes | ||||||
— HiGraph® | Yes | ||||||
configuration / programming / number of simultaneously active SFC / header | |||||||
— number of simultaneously active system functions (SFC) / with DPSYC_FR | 2; SFC 11; per interface | ||||||
— number of simultaneously active system functions (SFC) / with D_ACT_DP | 8; SFC 12; per interface | ||||||
— RD_REC | 8; SFC 59; per interface | ||||||
— WR_REC | 8; SFC 58; per interface | ||||||
— WR_PARM | 8; SFC 55; per interface | ||||||
— PARM_MOD | 1; SFC 57; per interface | ||||||
— WR_DPARM | 2; SFC 56; per interface | ||||||
— DPNRM_DG | 8; SFC 13; per interface | ||||||
— RDSYSST | 8; SFC 51 | ||||||
— DP_TOPOL | 1; SFC 103; per interface | ||||||
configuration / programming / number of simultaneously active SFB / header | |||||||
— RDREC — WRREC |
8; SFB 52; per interface, but not more than 32 across all external interfaces 8; SFB 53; per interface, but not more than 32 across all external interfaces |
||||||
Know-how protection | |||||||
● User program protection/password protection ● Block encryption |
Yes Yes; With S7 block Privacy |
||||||
Dimensions | |||||||
Width | 25 mm 290 mm 219 mm |
||||||
Height | |||||||
Depth | |||||||
Weights | |||||||
Weight, approx. | 700 g |