Input ranges | |||||||||||
● Voltage | Yes | ||||||||||
● Current | Yes | ||||||||||
● Thermocouple | Yes | ||||||||||
● Resistance thermometer | Yes | ||||||||||
● Resistance | Yes | ||||||||||
Input ranges (rated values), voltages | |||||||||||
● 0 to +10 V | No | ||||||||||
● 1 V to 5 V | Yes | ||||||||||
— Input resistance (1 V to 5 V) | 100 kΩ | ||||||||||
● 1 V to 10 V | No | ||||||||||
● -1 V to +1 V | Yes | ||||||||||
— Input resistance (-1 V to +1 V) | 10 MΩ | ||||||||||
● -10 V to +10 V | Yes | ||||||||||
— Input resistance (-10 V to +10 V) | 100 kΩ | ||||||||||
● -2.5 V to +2.5 V | Yes | ||||||||||
— Input resistance (-2.5 V to +2.5 V) | 100 kΩ | ||||||||||
● -250 mV to +250 mV | Yes | ||||||||||
— Input resistance (-250 mV to +250 mV) | 10 MΩ | ||||||||||
● -5 V to +5 V | Yes | ||||||||||
— Input resistance (-5 V to +5 V) | 100 kΩ | ||||||||||
● -50 mV to +50 mV | No | ||||||||||
|
|||||||||||
● -500 mV to +500 mV — Input resistance (-500 mV to +500 mV) ● -80 mV to +80 mV — Input resistance (-80 mV to +80 mV) |
Yes 10 MΩ Yes 10 MΩ |
||||||||||
Input ranges (rated values), currents | |||||||||||
● 0 to 20 mA — Input resistance (0 to 20 mA) ● -10 mA to +10 mA — Input resistance (-10 mA to +10 mA) ● -20 mA to +20 mA — Input resistance (-20 mA to +20 mA) ● -3.2 mA to +3.2 mA — Input resistance (-3.2 mA to +3.2 mA) ● 4 mA to 20 mA — Input resistance (4 mA to 20 mA) |
Yes 25 Ω Yes 25 Ω Yes 25 Ω Yes 25 Ω Yes 25 Ω |
||||||||||
Input ranges (rated values), thermocouples | |||||||||||
● Type B ● Type C ● Type E — Input resistance (Type E) ● Type J — Input resistance (type J) ● Type K — Input resistance (Type K) ● Type L — Input resistance (Type L) ● Type N — Input resistance (Type N) ● Type R ● Type S ● Type T ● Type U ● Type TXK/TXK(L) to GOST |
No No Yes 10 MΩ Yes 10 MΩ Yes 10 MΩ Yes 10 MΩ Yes 10 MΩ No No No No No |
||||||||||
Input ranges (rated values), resistance thermometer | |||||||||||
● Cu 10 ● Ni 100 — Input resistance (Ni 100) ● Ni 1000 ● LG-Ni 1000 ● Ni 120 ● Ni 200 ● Ni 500 ● Pt 100 — Input resistance (Pt 100) ● Pt 1000 ● Pt 200 ● Pt 500 |
No Yes; Standard 10 MΩ No No No No No Yes; Standard 10 MΩ No No No |
||||||||||
Input ranges (rated values), resistors | |||||||||||
● 0 to 150 ohms — Input resistance (0 to 150 ohms) ● 0 to 300 ohms — Input resistance (0 to 300 ohms) ● 0 to 600 ohms — Input resistance (0 to 600 ohms) ● 0 to 6000 ohms |
Yes 10 MΩ Yes 10 MΩ Yes 10 MΩ No |
||||||||||
Thermocouple (TC) | |||||||||||
Temperature compensation | |||||||||||
— parameterizable — internal temperature compensation — external temperature compensation with compensations socket |
Yes
Yes Yes |
||||||||||
— for definable comparison point temperature | Yes | ||||||||||
Characteristic linearization | |||||||||||
● parameterizable — for thermocouples — for resistance thermometer |
Yes Type E, J, K, L, N Pt100 (standard, climatic range), Ni100 (standard, climatic range) |
||||||||||
Cable length | |||||||||||
● shielded, max. | 200 m; 50 m at 80 mV and thermocouples | ||||||||||
Analog value generation for the inputs | |||||||||||
Integration and conversion time/resolution per channel | |||||||||||
● Resolution with overrange (bit including sign), max. ● Integration time, parameterizable ● Basic conversion time (ms) ● Interference voltage suppression for interference frequency f1 in Hz |
15 bit; Unipolar: 9/12/12/14 bit; bipolar: 9 bit + sign/12 bit + sign/12 bit + sign/14 bit + sign Yes; 2,5 / 16,67 / 20 / 100 ms 3 / 17 / 22 / 102 ms 400 / 60 / 50 / 10 Hz |
||||||||||
Encoder | |||||||||||
Connection of signal encoders | |||||||||||
● for voltage measurement ● for current measurement as 2-wire transducer ● for current measurement as 4-wire transducer ● for resistance measurement with two-wire connection ● for resistance measurement with three-wire connection ● for resistance measurement with four-wire connection |
Yes
Yes Yes Yes Yes Yes |
||||||||||
Errors/accuracies | |||||||||||
Operational error limit in overall temperature range | |||||||||||
● Voltage, relative to input range, (+/-) ● Current, relative to input range, (+/-) ● Resistance, relative to input range, (+/-) ● Resistance thermometer, relative to input range, (+/-) ● Thermocouple, relative to input range, (+/-) |
1 %; ±1% (80 mV); ±0.6% (250 mV to 1 000 mV); ±0.8% (2.5 V to 10 V) 0.7 %; From 3.2 to 20 mA 0.7 %; 150, 300, 600 Ohm 0.7 %; ±0.7 % (Pt100/ Ni100); ±0.8 % (Pt100 climate) 1.1 %; Type E, J, K, L, N |
||||||||||
Basic error limit (operational limit at 25 °C) | |||||||||||
● Voltage, relative to input range, (+/-) ● Current, relative to input range, (+/-) ● Resistance, relative to input range, (+/-) ● Resistance thermometer, relative to input range, (+/-) ● Thermocouple, relative to input range, (+/-) |
0.6 %; ±0.4 % (250 mV to 1 000 mV); ±0.6 % (2.5 mV to 10 mV); ±0.7 % (80 mV) 0.5 %; 3.2 to 20 mA 0.5 %; 150, 300, 600 Ohm 0.6 %; ±0.5% (Pt100/ Ni100), ±0.6% (Pt100 climate) 0.7 %; Type E, N, J, K, L |
||||||||||
Interrupts/diagnostics/status information | |||||||||||
Diagnostics function | Yes; Parameterizable | ||||||||||
Alarms | |||||||||||
● Diagnostic alarm ● Limit value alarm |
Yes; Parameterizable, channels 0 and 2 Yes; Parameterizable | ||||||||||
Diagnoses | |||||||||||
● Diagnostic information readable | Yes | ||||||||||
Diagnostics indication LED | |||||||||||
● Group error SF (red) | Yes | ||||||||||
Potential separation | |||||||||||
Potential separation analog inputs | |||||||||||
● between the channels ● between the channels and backplane bus ● between the channels and the power supply of the electronics |
No
Yes Yes |
||||||||||
Isolation | |||||||||||
Isolation tested with | 500 V DC | ||||||||||
connection method | |||||||||||
required front connector | 20-pin | ||||||||||
Dimensions | |||||||||||
Width | 40 mm 125 mm 117 mm |
||||||||||
Height | |||||||||||
Depth | |||||||||||
Weights | |||||||||||
Weight, approx. | 250 g |
SIMENS-6ES7331-7KF02-0AB0
SIMATIC S7-300, Analog input SM 331, isolated, 8 AI, Resolution 9/12/14 bits,
U/I/thermocouple/resistor, alarm, diagnostics, 1x 20-pole Removing/inserting with
active backplane bus
Category: Automation & Instrumentation
Description
Additional information
Dimensions | 40 × 125 × 117 cm |
---|---|
Input current |
from backplane bus 5 V DC, max. 90 mA |
Power loss, typ |
1 w |
Analog inputs |
Analog inputs Number of analog inputs 8 ● For resistance measurement 4, permissible input current for current input (destruction limit), max. 40 mA Constant measurement current for resistance-type transmitter, typ. 1.67 mA, permissible input voltage for voltage input (destruction limit), max. 20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20) |
Supply voltage |
● Reverse polarity protection Yes |
Brand |
SIEMENS |
Reviews (0)
Be the first to review “SIMENS-6ES7331-7KF02-0AB0” Cancel reply
Shipping & Delivery
Reviews
There are no reviews yet.