Battery | |||||||
Backup battery | |||||||
● Backup current, typ. ● Backup current, max. ● Backup time, max. ● Feeding of external backup voltage to CPU |
180 µA; up to 40 °C 850 µA Dealt with in the module data manual with the secondary conditions and the factors of influence 5 V DC to 15 V DC |
||||||
CPU processing times | |||||||
for bit operations, typ. | 31.25 ns 31.25 ns 31.25 ns 62.5 ns |
||||||
for word operations, typ. | |||||||
for fixed point arithmetic, typ. | |||||||
for floating point arithmetic, typ. | |||||||
CPU-blocks | |||||||
DB | |||||||
● Number, max. ● Size, max. |
3 000; Number range: 1 to 16000 64 kbyte |
||||||
FB | |||||||
● Number, max. ● Size, max. |
1 500; Number range: 0 to 7999 64 kbyte |
||||||
FC | |||||||
● Number, max. ● Size, max. |
1 500; Number range: 0 to 7999 64 kbyte |
||||||
OB | |||||||
● Number, max. ● Size, max. ● Number of free cycle OBs ● Number of time alarm OBs ● Number of delay alarm OBs ● Number of cyclic interrupt OBs ● Number of process alarm OBs ● Number of DPV1 alarm OBs ● Number of isochronous mode OBs ● Number of multicomputing OBs ● Number of background OBs ● Number of startup OBs ● Number of asynchronous error OBs ● Number of synchronous error OBs |
see instruction list 64 kbyte 1; OB 1 2; OB 10, 11 2; OB 20, 21 2; OB 32, 35 (shortest cycle that can be set = 500 µs) 2; OB 40, 41 3; OB 55-57 2; OB 61-62 1; OB 60 1; OB 90 3; OB 100-102 9; OB 80-88 2; OB 121, 122 |
||||||
Nesting depth | |||||||
● per priority class ● additional within an error OB |
24 1 |
||||||
Counters, timers and their retentivity | |||||||
S7 counter | |||||||
● Number | 2 048 | ||||||
Retentivity | |||||||
— adjustable — lower limit — upper limit — preset |
Yes 0 2 047 Z 0 to Z 7 |
||||||
Counting range | |||||||
— lower limit — upper limit |
0 999 |
||||||
IEC counter | |||||||
● present ● Type ● Number |
Yes SFB Unlimited (limited only by RAM capacity) |
||||||
S7 times | |||||||
● Number | 2 048 | ||||||
Retentivity | |||||||
— adjustable — lower limit — upper limit — preset |
Yes 0 2 047 No times retentive |
||||||
Time range | |||||||
— lower limit — upper limit |
10 ms 9 990 s |
||||||
IEC timer | |||||||
● present ● Type ● Number |
Yes SFB Unlimited (limited only by RAM capacity) |
||||||
Data areas and their retentivity | |||||||
Retentive data area (incl. timers, counters, flags), max. | Total working and load memory (with backup battery) | ||||||
Flag | |||||||
● Size, max. ● Retentivity available ● Retentivity preset ● Number of clock memories |
4 kbyte; Size of bit memory address area Yes MB 0 to MB 15 8; in 1 memory byte |
||||||
Local data | |||||||
● adjustable, max. ● preset |
8 kbyte 4 kbyte |
||||||
Address area | |||||||
I/O address area | |||||||
● Inputs ● Outputs |
4 kbyte 4 kbyte |
||||||
Process image | |||||||
● Inputs, adjustable ● Outputs, adjustable ● Inputs, default ● Outputs, default ● consistent data, max. ● Access to consistent data in process image |
4 kbyte 4 kbyte 128 byte 128 byte 244 byte Yes |
||||||
Subprocess images | |||||||
● Number of subprocess images, max. | 15 | ||||||
Digital channels | |||||||
● Inputs — of which central ● Outputs — of which central |
32 768 32 768 32 768 32 768 |
||||||
Analog channels | |||||||
● Inputs — of which central ● Outputs — of which central |
2 048 2 048 2 048 2 048 |
||||||
Hardware configuration | |||||||
Number of expansion units, max. | 21 47 Yes; 4 CPUs max. (with UR1 or UR2) |
||||||
connectable OPs | |||||||
Multicomputing | |||||||
Interface modules | |||||||
● Number of connectable IMs (total), max. ● Number of connectable IM 460s, max. ● Number of connectable IM 463s, max. |
6 6 4; IM 463-2 |
||||||
Number of DP masters | |||||||
● integrated ● via CP ● via IM 467 ● Mixed mode IM + CP permitted ● via interface module ● Number of pluggable S5 modules (via adapter capsule in central device), max. |
1 10; CP 443-5 Extended 4 No; IM 467 cannot be used jointly with CP 443-5 Ext. or CP 443-1 in PROFINET IO mode 0 6 |
||||||
Number of IO Controllers | |||||||
● integrated ● via CP |
0 4; Max. 4 in the central controller; no mixed operation of different CP 443-1 types in PROFINET IO mode |
||||||
Number of operable FMs and CPs (recommended) | |||||||
● FM ● CP, PtP ● PROFIBUS and Ethernet CPs |
Limited by number of slots and number of connections CP 440: Limited by number of slots; CP 441: Limited by number of slots and number of connections 14; In total max. 10 CPs as DP master and PROFINET controller, of which up to 10 IMs or CPs as DP master and up to 4 CPs as PROFINET controller |
||||||
Slots | |||||||
● required slots | 1 | ||||||
Time of day | |||||||
Clock | |||||||
● Hardware clock (real-time) ● retentive and synchronizable ● Resolution ● Deviation per day (buffered), max. ● Deviation per day (unbuffered), max. |
Yes Yes 1 ms 1.7 s; Power off 8.6 s; For power On |
||||||
Operating hours counter | |||||||
● Number ● Number/Number range ● Range of values ● Granularity ● retentive |
16 0 to 15 SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 – 1 hours 1 h Yes |
||||||
Clock synchronization | |||||||
● supported ● to MPI, master ● to MPI, slave ● to DP, master ● to DP, slave ● in AS, master ● in AS, slave ● on Ethernet via NTP ● to IF 964 DP |
Yes
Yes Yes Yes Yes Yes Yes |
||||||
Time difference in system when synchronizing via | |||||||
● MPI, max. | 200 ms | ||||||
Interfaces | |||||||
Interfaces/bus type | 1 x MPI/PROFIBUS DP 1; Combined MPI / PROFIBUS DP |
||||||
Number of RS 485 interfaces | |||||||
1. Interface | |||||||
Interface type | MPI/PROFIBUS DP Yes |
||||||
Isolated | |||||||
Interface types | |||||||
● RS 485 ● Output current of the interface, max. |
Yes 150 mA | ||||||
Protocols | |||||||
● MPI ● PROFIBUS DP master ● PROFIBUS DP slave |
Yes
Yes Yes |
||||||
MPI | |||||||
● Number of connections ● Transmission rate, max. |
32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 12 Mbit/s |
||||||
Services | |||||||
— PG/OP communication — Routing — Global data communication — S7 basic communication — S7 communication — S7 communication, as client — S7 communication, as server |
Yes
Yes Yes Yes Yes Yes Yes |
||||||
PROFIBUS DP master | |||||||
● Number of connections, max. ● Transmission rate, max. ● Number of DP slaves, max. |
16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 12 Mbit/s 32 |
||||||
Services | |||||||
— PG/OP communication | Yes | ||||||
— Routing | Yes; S7 routing | ||||||
— Global data communication | No | ||||||
— S7 basic communication | Yes | ||||||
— S7 communication | Yes | ||||||
— S7 communication, as client | Yes | ||||||
— S7 communication, as server | Yes | ||||||
— Equidistance | Yes | ||||||
— Isochronous mode | Yes | ||||||
— SYNC/FREEZE | Yes | ||||||
— Activation/deactivation of DP slaves | Yes | ||||||
— Direct data exchange (slave-to-slave communication) | Yes | ||||||
— DPV1 | Yes | ||||||
Address area | |||||||
— Inputs, max. — Outputs, max. |
2 kbyte 2 kbyte |
||||||
User data per DP slave | |||||||
— User data per DP slave, max. | 244 byte | ||||||
— Inputs, max. | 244 byte | ||||||
— Outputs, max. | 244 byte | ||||||
— Slots, max. | 244 | ||||||
— per slot, max. | 128 byte | ||||||
PROFIBUS DP slave | |||||||
● Number of connections | 16 | ||||||
● GSD file | http://support.automation.siemens.com/WW/view/en/113652 | ||||||
● Transmission rate, max. | 12 Mbit/s | ||||||
● automatic baud rate search | No | ||||||
● Address area, max. | 32; Virtual slots | ||||||
● User data per address area, max. | 32 byte | ||||||
— of which consistent, max. | 32 byte | ||||||
Services | |||||||
— PG/OP communication | Yes; with interface active | ||||||
— Routing | Yes; with interface active | ||||||
— Global data communication | No | ||||||
— S7 basic communication | No | ||||||
— S7 communication | Yes | ||||||
— S7 communication, as client | Yes | ||||||
— S7 communication, as server | Yes | ||||||
— Direct data exchange (slave-to-slave communication) | No | ||||||
— DPV1 | No | ||||||
Transfer memory | |||||||
— Inputs — Outputs |
244 byte 244 byte |
||||||
Protocols | |||||||
Open IE communication | |||||||
● ISO-on-TCP (RFC1006) — Data length, max. |
Via CP 443-1 Adv. and loadable FB 1 452 bytes via CP 443-1 Adv. | ||||||
Web server | |||||||
● supported | No | ||||||
Isochronous mode | |||||||
Equidistance | Yes | ||||||
Number of DP masters with isochronous mode | 1 | ||||||
User data per isochronous slave, max. | 244 byte | ||||||
shortest clock pulse | 1.5 ms; 0.5 ms without use of SFC 126, 127 | ||||||
max. cycle | 32 ms | ||||||
communication functions / header | |||||||
PG/OP communication ● Number of connectable OPs without message processing |
Yes 47 |
||||||
● Number of connectable OPs with message processing | 47; When using Alarm_S/SQ and Alarm_D/DQ | ||||||
Data record routing | Yes | ||||||
Global data communication | |||||||
● supported | Yes | ||||||
● Number of GD loops, max. | 8 | ||||||
● Number of GD packets, transmitter, max. | 8 | ||||||
● Number of GD packets, receiver, max. | 16 | ||||||
● Size of GD packets, max. | 54 byte | ||||||
● Size of GD packet (of which consistent), max. | 1 variable | ||||||
S7 basic communication | |||||||
● supported ● User data per job, max. ● User data per job (of which consistent), max. |
Yes 76 byte 1 variable |
||||||
S7 communication | |||||||
● supported | Yes | ||||||
● as server | Yes | ||||||
● as client | Yes | ||||||
● User data per job, max. | 64 kbyte | ||||||
● User data per job (of which consistent), max. | 462 byte | ||||||
S5 compatible communication | |||||||
● supported | Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 | ||||||
● User data per job, max. | 8 kbyte | ||||||
● User data per job (of which consistent), max. | 240 byte | ||||||
● Number of simultaneous AG-SEND/AG-RECV orders per CPU, max. | 24/24 | ||||||
Standard communication (FMS) | |||||||
● supported | Yes; Via CP and loadable FB | ||||||
Number of connections | |||||||
● overall | 48 | ||||||
● usable for PG communication | 47 | ||||||
— reserved for PG communication | 1 | ||||||
— adjustable for PG communication, max. | 0 | ||||||
● usable for OP communication | 47 | ||||||
— reserved for OP communication | 1 | ||||||
— adjustable for OP communication, max. | 0 | ||||||
● usable for S7 basic communication | 46 | ||||||
— reserved for S7 basic communication | 0 | ||||||
— adjustable for S7 basic communication, max. | 0 | ||||||
● usable for S7 communication | 46 | ||||||
— reserved for S7 communication | 0 | ||||||
— adjustable for S7 communication, max. | 0 | ||||||
● usable for routing | 23 | ||||||
— reserved for routing | 0 | ||||||
— adjustable for routing, max. | 0 | ||||||
S7 message functions | |||||||
Number of login stations for message functions, max. | 47; Max. 47 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC) | ||||||
Symbol-related messages | Yes | ||||||
SCAN procedure | Yes | ||||||
Program alarms | Yes | ||||||
Process diagnostic messages | Yes | ||||||
simultaneously active Alarm-S blocks, max. | 250; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks | ||||||
Alarm 8-blocks | Yes | ||||||
● Number of instances for alarm 8 and S7 communication blocks, max. | 300 | ||||||
● preset, max. | 150 | ||||||
Process control messages | Yes | ||||||
Number of archives that can log on simultaneously (SFB 37 AR_SEND) | 4 | ||||||
Number of messages | |||||||
● overall, max. | 256 | ||||||
● in 100 ms grid, max. | 0 | ||||||
● in 500 ms grid, max. ● in 1000 ms grid, max. |
256 256 |
||||||
Number of additional values | |||||||
● with 100 ms grid, max. ● with 500, 1000 ms grid, max. |
0 1 |
||||||
Test commissioning functions | |||||||
Status block | Yes; Up to 16 simultaneously Yes 16 |
||||||
Single step | |||||||
Number of breakpoints | |||||||
Status/control | |||||||
● Status/control variable ● Variables ● Number of variables, max. |
Yes; Up to 16 variable tables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters 70; Status/control |
||||||
Forcing | |||||||
● Forcing ● Forcing, variables ● Number of variables, max. |
Yes Inputs/outputs, bit memories, distributed I/Os 64 |
||||||
Diagnostic buffer | |||||||
● present ● Number of entries, max. — adjustable — preset |
Yes 3 200 Yes 120 |
||||||
Service data | |||||||
● can be read out | Yes | ||||||
Standards, approvals, certificates | |||||||
CE mark | Yes
Yes Yes Yes Yes Yes Yes |
||||||
CSA approval | |||||||
UL approval | |||||||
cULus | |||||||
FM approval | |||||||
RCM (formerly C-TICK) | |||||||
KC approval | |||||||
EAC (formerly Gost-R) | |||||||
Use in hazardous areas | |||||||
● ATEX | ATEX II 3G Ex nA IIC T4 Gc | ||||||
Ambient conditions | |||||||
Ambient temperature during operation | |||||||
● min. ● max. |
0 °C 60 °C |
||||||
configuration / header | |||||||
Configuration software | |||||||
● STEP 7 | Yes | ||||||
configuration / programming / header | |||||||
● Command set ● Nesting levels ● Access to consistent data in process image ● System functions (SFC) ● System function blocks (SFB) |
see instruction list 7 Yes see instruction list see instruction list |
||||||
Programming language | |||||||
— LAD — FBD — STL — SCL — CFC — GRAPH — HiGraph® |
Yes
Yes Yes Yes Yes Yes Yes |
||||||
configuration / programming / number of simultaneously active SFC / header | |||||||
— number of simultaneously active system functions (SFC) / with DPSYC_FR — number of simultaneously active system functions (SFC) / with D_ACT_DP |
2; SFC 11; per interface 8; SFC 12; per interface |
||||||
— RD_REC — WR_REC — WR_PARM — PARM_MOD — WR_DPARM — DPNRM_DG — RDSYSST — DP_TOPOL |
8; SFC 59; per interface 8; SFC 58; per interface 8; SFC 55; per interface 1; SFC 57; per interface 2; SFC 56; per interface 8; SFC 13; per interface 8; SFC 51 1; SFC 103; per interface |
||||||
configuration / programming / number of simultaneously active SFB / header | |||||||
— RDREC — WRREC |
8; SFB 52; per interface, but not more than 32 across all external interfaces 8; SFB 53; per interface, but not more than 32 across all external interfaces | ||||||
Know-how protection | |||||||
● User program protection/password protection ● Block encryption |
Yes Yes; With S7 block Privacy |
||||||
Dimensions | |||||||
Width | 25 mm 290 mm 219 mm |
||||||
Height | |||||||
Depth | |||||||
Weights | |||||||
Weight, approx. | 700 g | ||||||