CPU-blocks | ||||||
Number of blocks (total) | 2 048; (DBs, FCs, FBs OBs, SDBs); the maximum number of loadable blocks can be reduced by the MMC being used. | |||||
DB | ||||||
● Number, max. ● Size, max. |
2 047; Number band: 1 to 2047 64 kbyte |
|||||
FB | ||||||
● Number, max. ● Size, max. |
2 048; Number range: 0 to 2047 64 kbyte |
|||||
FC | ||||||
● Number, max. ● Size, max. |
2 048; Number range: 0 to 2047 64 kbyte |
|||||
OB | ||||||
● Size, max. ● Number of free cycle OBs ● Number of time alarm OBs ● Number of delay alarm OBs ● Number of cyclic interrupt OBs ● Number of process alarm OBs ● Number of DPV1 alarm OBs ● Number of isochronous mode OBs ● Number of startup OBs ● Number of asynchronous error OBs ● Number of synchronous error OBs |
64 kbyte 1; OB 1 1; OB 10 2; OB 20, 21 4; OB 32, 33, 34, 35 1; OB 40 3; OB 55, 56, 57 1; OB 61 1; OB 100 5; OB 80, 82, 85, 86, 87 2; OB 121, 122 |
|||||
Nesting depth | ||||||
● per priority class ● additional within an error OB |
16 4 |
|||||
Counters, timers and their retentivity | ||||||
S7 counter | ||||||
● Number | 512 | |||||
Retentivity | ||||||
— adjustable — lower limit — upper limit — preset |
Yes 0 511 Z 0 to Z 7 |
|||||
Counting range | ||||||
— adjustable — lower limit — upper limit |
Yes 0 999 |
|||||
IEC counter | ||||||
● present ● Type ● Number |
Yes SFB Unlimited (limited only by RAM capacity) |
|||||
S7 times | ||||||
● Number | 512 | |||||
Retentivity | ||||||
— adjustable — lower limit — upper limit — preset |
Yes 0 511 No retentivity |
|||||
Time range | ||||||
— lower limit — upper limit |
10 ms 9 990 s |
|||||
IEC timer | ||||||
● present ● Type ● Number |
Yes SFB Unlimited (limited only by RAM capacity) |
|||||
Data areas and their retentivity | ||||||
Retentive data area (incl. timers, counters, flags), max. | 256 kbyte | |||||
Flag | ||||||
● Size, max. ● Retentivity available ● Retentivity preset ● Number of clock memories |
4 096 byte Yes; From MB 0 to MB 4 095 MB 0 to MB 15 8; 1 memory byte |
|||||
Data blocks | ||||||
● Retentivity adjustable ● Retentivity preset |
Yes; via non-retain property on DB Yes | |||||
Local data | ||||||
● per priority class, max. | 1 024 byte | |||||
Address area | ||||||
I/O address area | ||||||
● Inputs ● Outputs |
8 192 byte 8 192 byte |
|||||
of which distributed | ||||||
— Inputs — Outputs |
8 192 byte 8 192 byte |
|||||
Process image | ||||||
● Inputs ● Outputs ● Inputs, adjustable ● Outputs, adjustable ● Inputs, default ● Outputs, default |
2 048 byte 2 048 byte 2 048 byte 2 048 byte 256 byte 256 byte |
|||||
Subprocess images | ||||||
● Number of subprocess images, max. | 1 | |||||
Digital channels | ||||||
● Inputs — of which central ● Outputs — of which central |
65 536 1 024 65 536 1 024 |
|||||
Analog channels | ||||||
● Inputs — of which central ● Outputs — of which central |
4 096 256 4 096 256 |
|||||
Hardware configuration | ||||||
Number of expansion units, max. | 3 | |||||
Number of DP masters | ||||||
● integrated ● via CP |
2 4 |
|||||
Number of operable FMs and CPs (recommended) | ||||||
● FM ● CP, PtP ● CP, LAN |
8 8 10 |
|||||
Rack | ||||||
● Racks, max. ● Modules per rack, max. |
4 8 |
|||||
Time of day | ||||||
Clock | ||||||
● Hardware clock (real-time) ● retentive and synchronizable ● Backup time ● Deviation per day, max. ● Behavior of the clock following POWER-ON ● Behavior of the clock following expiry of backup period |
Yes Yes 6 wk; At 40 °C ambient temperature 10 s Clock continues running after POWER OFF the clock continues at the time of day it had when power was switched off |
|||||
Operating hours counter | ||||||
● Number ● Number/Number range ● Range of values ● Granularity ● retentive |
4 0 to 3 0 to 2^31 hours (when using SFC 101) 1 h Yes; Must be restarted at each restart |
|||||
Clock synchronization | ||||||
● supported ● to MPI, master ● to MPI, slave ● to DP, master ● to DP, slave |
Yes Yes Yes Yes; With DP slave only slave clock Yes |
|||||
● in AS, master ● in AS, slave ● on Ethernet via NTP |
Yes Yes No |
|||||
Digital inputs | ||||||
integrated channels (DI) | 0 | |||||
Digital outputs | ||||||
integrated channels (DO) | 0 | |||||
Analog inputs | ||||||
integrated channels (AI) | 0 | |||||
Analog outputs | ||||||
integrated channels (AO) | 0 | |||||
Interfaces | ||||||
Number of industrial Ethernet interfaces | 0 0 2; Combined MPI / PROFIBUS DP and PROFIBUS DP 0 |
|||||
Number of PROFINET interfaces | ||||||
Number of RS 485 interfaces | ||||||
Number of RS 422 interfaces | ||||||
1. Interface | ||||||
Interface type | Integrated RS 485 interface Yes |
|||||
Isolated | ||||||
Interface types | ||||||
● RS 485 ● Output current of the interface, max. |
Yes 200 mA |
|||||
Protocols | ||||||
● MPI ● PROFIBUS DP master ● PROFIBUS DP slave ● Point-to-point connection |
Yes Yes Yes No |
|||||
MPI | ||||||
● Number of connections ● Transmission rate, max. |
32 12 Mbit/s |
|||||
Services | ||||||
— PG/OP communication — Routing — Global data communication — S7 basic communication — S7 communication — S7 communication, as client — S7 communication, as server |
Yes Yes Yes Yes Yes No Yes |
|||||
PROFIBUS DP master | ||||||
● Transmission rate, max. ● Number of DP slaves, max. |
12 Mbit/s 124 |
|||||
Services | ||||||
— PG/OP communication — Routing — Global data communication — S7 basic communication — S7 communication — S7 communication, as client — S7 communication, as server — Equidistance — Isochronous mode — SYNC/FREEZE — Activation/deactivation of DP slaves — Number of DP slaves that can be simultaneously activated/deactivated, max. — DPV1 |
Yes Yes No Yes; I blocks only Yes No Yes Yes No Yes Yes 4 Yes |
|||||
Address area | ||||||
— Inputs, max. — Outputs, max. |
8 096 byte 8 096 byte |
|||||
User data per DP slave | ||||||
— Inputs, max. | 244 byte | |||||
— Outputs, max. | 244 byte | |||||
PROFIBUS DP slave | ||||||
● Transmission rate, max. | 12 Mbit/s | |||||
● automatic baud rate search | Yes; only with passive interface | |||||
● Address area, max. | 32 | |||||
● User data per address area, max. | 32 byte | |||||
Services | ||||||
— PG/OP communication | Yes | |||||
— Routing | Yes; Only with active interface | |||||
— Global data communication | No | |||||
— S7 basic communication | No | |||||
— S7 communication | Yes | |||||
— S7 communication, as client | No | |||||
— S7 communication, as server | Yes | |||||
— Direct data exchange (slave-to-slave communication) | Yes | |||||
— DPV1 | No | |||||
Transfer memory | ||||||
— Inputs — Outputs |
244 byte 244 byte |
|||||
2. Interface | ||||||
Interface type | Integrated RS 485 interface Yes |
|||||
Isolated | ||||||
Interface types | ||||||
● RS 485 ● Output current of the interface, max. |
Yes 200 mA |
|||||
Protocols | ||||||
● MPI | No | |||||
● PROFIBUS DP master | Yes | |||||
● PROFIBUS DP slave | Yes | |||||
● Point-to-point connection | No | |||||
PROFIBUS DP master | ||||||
● Number of connections, max. | 32 | |||||
● Transmission rate, max. | 12 Mbit/s | |||||
● Number of DP slaves, max. | 124 | |||||
Services | ||||||
— PG/OP communication | Yes | |||||
— Routing | Yes | |||||
— Global data communication | No | |||||
— S7 basic communication | Yes; I blocks only | |||||
— S7 communication | Yes | |||||
— S7 communication, as client | No | |||||
— S7 communication, as server | Yes | |||||
— Equidistance | Yes | |||||
— Isochronous mode | Yes; OB 61 | |||||
— SYNC/FREEZE | Yes | |||||
— Activation/deactivation of DP slaves | Yes | |||||
— DPV1 | Yes | |||||
Address area | ||||||
— Inputs, max. — Outputs, max. |
8 096 byte 8 096 byte |
|||||
User data per DP slave | ||||||
— Inputs, max. — Outputs, max. |
244 byte 244 byte |
|||||
PROFIBUS DP slave | ||||||
● Number of connections | 32 | |||||
● GSD file | The latest GSD file is available at: http://www.siemens.com/profibus-gsd | |||||
● Transmission rate, max. | 12 Mbit/s | |||||
● automatic baud rate search | Yes; only with passive interface | |||||
● Address area, max. | 32 | |||||
● User data per address area, max. | 32 byte | |||||
Services | ||||||
— PG/OP communication — Routing — Global data communication — S7 basic communication — S7 communication — S7 communication, as client — S7 communication, as server — Direct data exchange (slave-to-slave communication) — DPV1 |
Yes Yes; with interface active No No Yes No Yes Yes No |
|||||
Transfer memory | ||||||
— Inputs — Outputs |
244 byte 244 byte |
|||||
Protocols | ||||||
PROFIsafe | No | |||||
communication functions / header | ||||||
PG/OP communication | Yes No |
|||||
Data record routing | ||||||
Global data communication | ||||||
● supported | Yes | |||||
● Number of GD loops, max. | 8 | |||||
● Number of GD packets, max. | 8 | |||||
● Number of GD packets, transmitter, max. | 8 | |||||
● Number of GD packets, receiver, max. | 8 | |||||
● Size of GD packets, max. | 22 byte | |||||
● Size of GD packet (of which consistent), max. | 22 byte | |||||
S7 basic communication | ||||||
● supported | Yes | |||||
● User data per job, max. | 76 byte | |||||
● User data per job (of which consistent), max. | 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) | |||||
S7 communication | ||||||
● supported | Yes | |||||
● as server | Yes | |||||
● as client | Yes; Via CP and loadable FB | |||||
● User data per job, max. | 180 byte; With PUT/GET | |||||
● User data per job (of which consistent), max. | 160 byte; as server | |||||
S5 compatible communication | ||||||
● supported | Yes; via CP and loadable FC | |||||
Number of connections | ||||||
● overall | 32 | |||||
● usable for PG communication | 31 | |||||
— reserved for PG communication | 1 | |||||
— adjustable for PG communication, min. | 1 | |||||
— adjustable for PG communication, max. | 31 | |||||
● usable for OP communication | 31 | |||||
— reserved for OP communication | 1 | |||||
— adjustable for OP communication, min. | 1 | |||||
— adjustable for OP communication, max. | 31 | |||||
● usable for S7 basic communication | 30 | |||||
— reserved for S7 basic communication | 0 | |||||
— adjustable for S7 basic communication, min. | 0 | |||||
— adjustable for S7 basic communication, max. | 30 | |||||
● usable for routing | 8 | |||||
S7 message functions | ||||||
Number of login stations for message functions, max. | 32; Depending on the configured connections for PG/OP and S7 basic | |||||
communication | ||||||
Process diagnostic messages | Yes | |||||
simultaneously active Alarm-S blocks, max. | 60 | |||||
Test commissioning functions | ||||||
Status block | Yes Yes 2 |
|||||
Single step | ||||||
Number of breakpoints | ||||||
Status/control | ||||||
● Status/control variable ● Variables ● Number of variables, max. — of which status variables, max. — of which control variables, max. |
Yes Inputs, outputs, memory bits, DB, times, counters 30 30 14 |
|||||
Forcing | ||||||
● Forcing ● Forcing, variables ● Number of variables, max. |
Yes Inputs, outputs 10 |
|||||
Diagnostic buffer | ||||||
● present ● Number of entries, max. — adjustable — of which powerfail-proof |
Yes 100 No 100 |
|||||
configuration / header | ||||||
Configuration software | ||||||
● STEP 7 | Yes; V5.2 SP1 or higher with HW update | |||||
configuration / programming / header | ||||||
● Command set ● Nesting levels ● System functions (SFC) ● System function blocks (SFB) |
see instruction list 8 see instruction list see instruction list |
|||||
Programming language | ||||||
— LAD — FBD — STL — SCL — CFC — GRAPH — HiGraph® |
Yes
Yes Yes Yes Yes Yes |
|||||
Know-how protection | ||||||
● User program protection/password protection | Yes | |||||
Dimensions | ||||||
Width | 80 mm 125 mm 130 mm |
|||||
Height | ||||||
Depth | ||||||
Weights | ||||||
Weight, approx. | 460 g |