CPU processing times | |
for bit operations, typ. | 150 ns; / instruction 1.2 µs; / instruction 3.6 µs; / instruction |
for word operations, typ. | |
for floating point arithmetic, typ. | |
Address area | |
I/O address area | |
● Inputs ● Outputs |
144 byte; 256 bit of digital inputs & 56 words of analog inputs 144 byte; 256 bit of digital outputs & 56 words of analog outputs |
Time of day | |
Clock | |
● Type ● Hardware clock (real-time) ● Backup time ● Deviation per day, max. |
Hardware clock, no battery backup Yes 7 d 120 s; within 120s/month at 25 °C |
Digital inputs | |
Number of digital inputs | 12 |
Input voltage | |
● Type of input voltage ● Rated value (DC) ● for signal “0” ● for signal “1” |
DC 24 V I0.0 to I0.3 < 1 V DC; I0.4 to I2.7 < 5 V DC I0.0 to I0.3 > 4V; I0.4 to I2.7 > 15V |
Input current | |
● for signal “0”, max. (permissible quiescent current) ● for signal “1”, typ. |
1 mA 4 mA |
Input delay (for rated value of input voltage) | |
for standard inputs | |
— parameterizable — at “0” to “1”, min. — at “0” to “1”, max. |
Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four 0.2 ms 12.8 ms |
for interrupt inputs | |
— parameterizable | Yes |
for technological functions | |
— parameterizable | Yes; 6 Single phase: 4 HSCs at 200 kHz; 2 HSCs at 30 kHz 4 A/B phase: 2 HSCs at 100 kHz; 2 HSCs at 20 kHz |
Cable length | |
● shielded, max. ● unshielded, max. |
500 m; 50 m for technological functions 300 m; for technological functions: No |
Digital outputs | |
Number of digital outputs ● of which high-speed outputs |
8; Transistor 3; 100 kHz Pulse Train Output No |
Short-circuit protection | |
Switching capacity of the outputs | |
● with resistive load, max. ● on lamp load, max. |
0.5 A 5 W |
Output voltage | |
● for signal “1”, min. | 20 V DC |
Output current | |
● for signal “1” rated value ● for signal “0” residual current, max. |
0.5 A 10 µA |
Output delay with resistive load | |
● “0” to “1”, max. ● “1” to “0”, max. |
3 µs; of the standard outputs, max. 3 µs; of the pulse outputs, max. (Q a.0 to Q a.3) 1 µs 200 µs; of the standard outputs, max. 200 µs; of the pulse outputs, max. (Q a.0 to Q a.3) 50 µs |
Switching frequency | |
● of the pulse outputs, with resistive load, max. | 100 kHz |
Relay outputs | |
● Number of relay outputs | 0 |
Cable length | |
● shielded, max. ● unshielded, max. |
500 m 150 m |
Interfaces | |
Number of industrial Ethernet interfaces | 1 1 |
Number of RS 485 interfaces | |
1. Interface | |
Interface type | PROFINET Yes; Transformer isolated, 1,500V AC Yes; 10/100 Mbit/s Yes Yes |
Isolated | |
automatic detection of transmission rate | |
Autonegotiation | |
Autocrossing | |
Interface types | |
● RJ 45 (Ethernet) | Yes |
Protocols | |
● PROFINET IO Controller ● PROFINET IO Device |
Yes; Since V2.4 Yes; I-Device since V2.5 |
PROFINET IO Controller | |
● Transmission rate, max. | 100 Mbit/s |
Services | |
— Number of connectable IO Devices, max. — Updating time |
8 4 ms; The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data. |
Address area | |
— Inputs, max. — Outputs, max. |
128 byte; Per device 128 byte; Per device |
2. Interface | |
Interface type | RS 485 (max. 187.5 kbps) |
Interface types | |
● RS 485 | Yes |
PROFIBUS DP master | |
Services | |
— S7 communication | Yes |
Protocols | |
Supports protocol for PROFINET IO | Yes; RT Controller (since FW V2.4) & I-Device (since FW V2.5) Yes; Via CM DP module |
PROFIBUS | |
Protocols (Ethernet) | |
● TCP/IP | Yes |
communication functions / header | |
S7 communication | |
● supported ● as server ● as client |
Yes Yes Yes |
Test commissioning functions | |
Forcing | |
● Forcing | Yes |
Integrated Functions | |
Counter ● Number of counters |
6 Yes; PID closed-loop control function: Continuous controller outputs, binary controller outputs, automatic/manual mode, max. 8 loops 3 |
PID controller | |
Number of pulse outputs | |
EMC | |
Interference immunity against discharge of static electricity | |
● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 — Test voltage at air discharge — Test voltage at contact discharge |
Yes 8 kV 4 kV |
Interference immunity against high-frequency electromagnetic fields | |
● Interference immunity against high-frequency radiation acc. to IEC 61000-4-3 | Yes; 10 V/m, 80 to 1 000 MHz (to IEC 61000-4-3); 10 V/m, 900 MHz, 1.89 GHz, 50% ED (to IEC 61000-4-3) |
Interference immunity to cable-borne interference | |
● Interference immunity on supply lines acc. to IEC 61000- 4-4 ● Interference immunity on signal cables acc. to IEC 61000- 4-4 |
Yes; 2 kV acc. to IEC 61000-4-4, burst Yes; ±2 kV acc. to IEC 61000-4-4, Burst |
Interference immunity against conducted variable disturbance induced by high-frequency fields | |
● Interference immunity against high frequency current feed acc. to IEC 61000-4-6 | Yes; 10 V, 150 kHz to 80 MHz (to IEC 61000-4-6) |
Emission of radio interference acc. to EN 55 011 | |
● Limit class A, for use in industrial areas | Yes; EN 61000-6-4, interference emission: Intended for use in industrial areas. |
Emission of conducted and non-conducted interference | |
● Interference emission via line/AC current cables | EN 61000-6-4, interference emission: Intended for use in industrial areas. |
Degree and class of protection | |
IP degree of protection | IP20 |
Standards, approvals, certificates | |
CE mark | Yes |
Ambient conditions | |
Free fall | |
● Fall height, max. | 0.3 m; five times, in product package |
Ambient temperature during operation | |
● min. ● max. ● horizontal installation, min. ● horizontal installation, max. ● vertical installation, min. ● vertical installation, max. |
0 °C 55 °C 0 °C 55 °C 0 °C 45 °C |
Ambient temperature during storage/transportation | |
● min. ● max. |
-40 °C 70 °C |
Air pressure acc. to IEC 60068-2-13 | |
● Storage/transport, min. ● Storage/transport, max. |
660 hPa 1 080 hPa |
Altitude during operation relating to sea level | |
● Installation altitude, min. ● Installation altitude, max. |
-1 000 m 2 000 m |
Relative humidity | |
● Operation at 25 ℃ without condensation, max. | 95 % |
configuration / header | |
configuration / programming / header | |
Programming language | |
— LAD — FBD — STL |
Yes Yes Yes |
Dimensions | |
Width | 90 mm 100 mm 81 mm |
Height | |
Depth | |
Weights | |
Weight, approx. | 320 g |
SIMENS-6ES7288-1ST20-0AA0
*** spare part *** SIMATIC S7-200 SMART, CPU ST20, standard CPU,
DC/DC/DC, onboard I/O: 12 DI 24 V DC; 8 DO 24 V DC; power supply: DC 20.4-
28.8V DC, program/data memory 20 KB
Category: Automation & Instrumentation
Description
Additional information
Dimensions | 90 × 100 × 81 cm |
---|---|
Product type designation |
CPU ST20 DC/DC/DC |
Programming package |
STEP 7 Micro/WIN SMART |
Rail mounting |
Yes; Standard – DIN rail |
Current consumption, max |
720 mA; 24 V DC |
Inrush current, max. |
11.7 A; at 28.8 V |
Current output, max |
300 mA; 24 V DC Sensor Power |
Power loss, max |
20 W |
Type of memory |
DDR |
Flash |
YES |
RAM |
YES |
Memory available |
8 kbytE |
Memory size |
12 kbyte; Program memory |
Micro Memory Card |
Yes; microSDHC Card (optional) |
Backup / present |
Yes; Maintenance free, RTC requires 7 days. |
Brand |
SIEMENS |
Reviews (0)
Be the first to review “SIMENS-6ES7288-1ST20-0AA0” Cancel reply
Shipping & Delivery
Reviews
There are no reviews yet.