CPU-blocks | |||||
Number of blocks (total) | DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used | ||||
OB | |||||
● Number, max. | Limited only by RAM for code | ||||
Data areas and their retentivity | |||||
Retentive data area (incl. timers, counters, flags), max. | 14 kbyte | ||||
Flag | |||||
● Size, max. | 4 kbyte; Size of bit memory address area | ||||
Local data | |||||
● per priority class, max. | 16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB | ||||
Address area | |||||
Process image | |||||
● Inputs, adjustable ● Outputs, adjustable |
1 kbyte 1 kbyte |
||||
Hardware configuration | |||||
Number of modules per system, max. | 3 communication modules, 1 signal board | ||||
Time of day | |||||
Clock | |||||
● Hardware clock (real-time) ● Backup time ● Deviation per day, max. |
Yes 480 h; Typical ±60 s/month at 25 °C |
||||
Digital inputs | |||||
Number of digital inputs ● of which inputs usable for technological functions |
6; Integrated 6; HSC (High Speed Counting) Yes |
||||
Source/sink input | |||||
Number of simultaneously controllable inputs | |||||
all mounting positions | |||||
— up to 40 °C, max. | 6 | ||||
Input voltage | |||||
● Rated value (DC) ● for signal “0” ● for signal “1” |
24 V 5 V DC at 1 mA 15 V DC at 2.5 mA |
||||
Input current | |||||
● for signal “1”, typ. | 4 mA; nominal | ||||
Input delay (for rated value of input voltage) | |||||
for standard inputs | |||||
— parameterizable | 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in | ||||
groups of four | |||||
— at “0” to “1”, min. | 0.2 ms | ||||
— at “0” to “1”, max. | 12.8 ms | ||||
for interrupt inputs | |||||
— parameterizable | Yes | ||||
for technological functions | |||||
— parameterizable | Single phase : 3 @ 100 kHz, differential: 3 @ 80 kHz | ||||
Cable length | |||||
● shielded, max. ● unshielded, max. |
500 m; 50 m for technological functions 300 m; for technological functions: No | ||||
Digital outputs | |||||
Number of digital outputs | 4; Relays | ||||
Switching capacity of the outputs | |||||
● with resistive load, max. ● on lamp load, max. |
2 A 30 W with DC, 200 W with AC |
||||
Output delay with resistive load | |||||
● “0” to “1”, max. ● “1” to “0”, max. |
10 ms; max. 10 ms; max. |
||||
Relay outputs | |||||
● Number of relay outputs | 4 | ||||
● Number of operating cycles, max. | mechanically 10 million, at rated load voltage 100 000 | ||||
Cable length | |||||
● shielded, max. ● unshielded, max. |
500 m 150 m |
||||
Analog inputs | |||||
Number of analog inputs | 2 | ||||
Input ranges | |||||
● Voltage | Yes | ||||
Input ranges (rated values), voltages | |||||
● 0 to +10 V — Input resistance (0 to 10 V) |
Yes ≥100k ohms |
||||
Cable length | |||||
● shielded, max. | 100 m; twisted and shielded | ||||
Analog outputs | |||||
Number of analog outputs | 0 | ||||
Analog value generation for the inputs | |||||
Integration and conversion time/resolution per channel | |||||
● Resolution with overrange (bit including sign), max. ● Integration time, parameterizable ● Conversion time (per channel) |
10 bit Yes 625 µs | ||||
Encoder | |||||
Connectable encoders | |||||
● 2-wire sensor | Yes | ||||
1. Interface | |||||
Interface type | PROFINET | ||||
Isolated | Yes | ||||
automatic detection of transmission rate | Yes | ||||
Autonegotiation | Yes | ||||
Autocrossing | Yes | ||||
Interface types | |||||
● RJ 45 (Ethernet) ● Number of ports ● integrated switch |
Yes 1 No |
||||
Protocols | |||||
● PROFINET IO Controller | Yes | ||||
● PROFINET IO Device | Yes | ||||
● SIMATIC communication | Yes | ||||
● Open IE communication | Yes; Optionally also encrypted | ||||
● Web server | Yes | ||||
● Media redundancy | No | ||||
PROFINET IO Controller | |||||
● Transmission rate, max. | 100 Mbit/s | ||||
Services | |||||
— PG/OP communication | Yes; encryption with TLS V1.3 pre-selected | ||||
— Isochronous mode | No | ||||
— IRT | No | ||||
— PROFIenergy | No | ||||
— Prioritized startup | Yes | ||||
— Number of IO devices with prioritized startup, max. | 16 | ||||
— Number of connectable IO Devices, max. | 16 | ||||
— Number of connectable IO Devices for RT, max. | 16 | ||||
— of which in line, max. | 16 | ||||
— Activation/deactivation of IO Devices | Yes | ||||
— Number of IO Devices that can be simultaneously | 8 | ||||
activated/deactivated, max. | |||||
— Updating time | The minimum value of the update time also depends on the communication | ||||
component set for PROFINET IO, on the number of IO devices and the quantity | |||||
of configured user data. | |||||
PROFINET IO Device | |||||
Services | |||||
— PG/OP communication | Yes; encryption with TLS V1.3 pre-selected | ||||
— Isochronous mode — IRT — PROFIenergy — Shared device — Number of IO Controllers with shared device, max. |
No No Yes Yes 2 |
||||
Protocols | |||||
Supports protocol for PROFINET IO | Yes | ||||
PROFIsafe | No | ||||
PROFIBUS | Yes; CM 1243-5 (master) or CM 1242-5 (slave) required | ||||
OPC UA | Yes; OPC UA Server | ||||
AS-Interface | Yes; CM 1243-2 required | ||||
Protocols (Ethernet) | |||||
● TCP/IP | Yes | ||||
● DHCP | No | ||||
● SNMP | Yes | ||||
● DCP | Yes | ||||
● LLDP | Yes | ||||
Redundancy mode | |||||
Media redundancy | |||||
— MRP — MRPD |
No No |
||||
SIMATIC communication | |||||
● S7 routing | Yes | ||||
Open IE communication | |||||
● TCP/IP | Yes | ||||
— Data length, max. | 8 kbyte | ||||
— several passive connections per port, supported | Yes | ||||
● ISO-on-TCP (RFC1006) | Yes | ||||
— Data length, max. | 8 kbyte | ||||
● UDP | Yes | ||||
— Data length, max. | 1 472 byte | ||||
Web server | |||||
● supported ● User-defined websites |
Yes Yes | ||||
OPC UA | |||||
● Runtime license required | Yes; “Basic” license required | ||||
● OPC UA Server | Yes; data access (read, write, subscribe), method call, runtime license required | ||||
— Application authentication | Available security policies: None, Basic128Rsa15, Basic256Rsa15, | ||||
Basic256Sha256 | |||||
— User authentication | “anonymous” or by user name & password | ||||
— Number of sessions, max. | 10 | ||||
— Number of subscriptions per session, max. | 5 | ||||
— Sampling interval, min. | 100 ms | ||||
— Publishing interval, min. | 200 ms | ||||
— Number of server methods, max. | 20 | ||||
— Number of monitored items, recommended max. | 1 000 | ||||
— Number of server interfaces, max. | 2 | ||||
— Number of nodes for user-defined server interfaces, | 2 000 | ||||
max. | |||||
Further protocols | |||||
● MODBUS | Yes | ||||
communication functions / header | |||||
S7 communication | |||||
● supported | Yes | ||||
● as server | Yes | ||||
● as client | Yes | ||||
● User data per job, max. | See online help (S7 communication, user data size) | ||||
Number of connections | |||||
● overall | PG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved / 10 max; Total Connections: 34 reserved / 64 max |
||||
Test commissioning functions | |||||
Status/control | |||||
● Status/control variable ● Variables |
Yes Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
||||
Forcing | |||||
● Forcing | Yes | ||||
Diagnostic buffer | |||||
● present | Yes | ||||
Traces | |||||
● Number of configurable Traces ● Memory size per trace, max. |
2 512 kbyte |
||||
Interrupts/diagnostics/status information | |||||
Diagnostics indication LED | |||||
● RUN/STOP LED ● ERROR LED ● MAINT LED |
Yes
Yes Yes |
||||
Integrated Functions | |||||
Counter ● Number of counters ● Counting frequency, max. |
6 100 kHz Yes Yes 8 Up to 4 with SB 1222 Yes 4 |
||||
Frequency measurement | |||||
controlled positioning | |||||
Number of position-controlled positioning axes, max. | |||||
Number of positioning axes via pulse-direction interface | |||||
PID controller | |||||
Number of alarm inputs | |||||
Potential separation | |||||
Potential separation digital inputs | |||||
● Potential separation digital inputs ● between the channels, in groups of |
500V AC for 1 minute 1 | ||||
Potential separation digital outputs | |||||
● Potential separation digital outputs ● between the channels ● between the channels, in groups of |
Relays No 1 |
||||
EMC | |||||
Interference immunity against discharge of static electricity | |||||
● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 — Test voltage at air discharge — Test voltage at contact discharge |
Yes 8 kV 6 kV |
||||
Interference immunity to cable-borne interference | |||||
● Interference immunity on supply lines acc. to IEC 61000- 4-4 ● Interference immunity on signal cables acc. to IEC 61000- 4-4 |
Yes Yes |
||||
Interference immunity against voltage surge | |||||
● Interference immunity on supply lines acc. to IEC 61000- 4-5 | Yes | ||||
Interference immunity against conducted variable disturbance induced by high-frequency fields | |||||
● Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 | Yes | ||||
Emission of radio interference acc. to EN 55 011 | |||||
● Limit class A, for use in industrial areas ● Limit class B, for use in residential areas |
Yes; Group 1 Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 |
||||
Degree and class of protection | |||||
IP degree of protection | IP20 | ||||
Standards, approvals, certificates | |||||
CE mark | Yes
Yes Yes |
||||
UL approval | |||||
cULus | |||||
FM approval | |||||
RCM (formerly C-TICK) | Yes YesYes |
||||
KC approval | |||||
Marine approval | |||||
Ambient conditions | |||||
Free fall | |||||
● Fall height, max. | 0.3 m; five times, in product package | ||||
Ambient temperature during operation | |||||
● min. ● max. ● horizontal installation, min. ● horizontal installation, max. ● vertical installation, min. ● vertical installation, max. |
-20 °C 60 °C -20 °C 60 °C -20 °C 50 °C |
||||
Ambient temperature during storage/transportation | |||||
● min. ● max. |
-40 °C 70 °C |
||||
Air pressure acc. to IEC 60068-2-13 | |||||
● Operation, min. ● Operation, max. ● Storage/transport, min. ● Storage/transport, max. |
795 hPa 1 080 hPa 660 hPa 1 080 hPa |
||||
Altitude during operation relating to sea level | |||||
● Installation altitude, min. ● Installation altitude, max. |
-1 000 m 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
||||
Relative humidity | |||||
● Operation, max. | 95 %; no condensation | ||||
Vibrations | |||||
● Vibration resistance during operation acc. to IEC 60068- 2-6 ● Operation, tested according to IEC 60068-2-6 |
2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail Yes |
||||
Shock testing | |||||
● tested according to IEC 60068-2-27 | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms | ||||
Pollutant concentrations | |||||
● SO2 at RH < 60% without condensation | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free | ||||
configuration / header | |||||
configuration / programming / header | |||||
Programming language | |||||
— LAD — FBD — SCL |
Yes
Yes Yes |
||||
Know-how protection | |||||
● User program protection/password protection ● Copy protection ● Block protection |
Yes
Yes Yes |
||||
Access protection | |||||
● protection of confidential configuration data ● Protection level: Write protection ● Protection level: Read/write protection ● Protection level: Complete protection |
Yes
Yes Yes Yes |
||||
programming / cycle time monitoring / header | |||||
● adjustable | Yes | ||||
Dimensions | |||||
Width | 90 mm 100 mm 75 mm |
||||
Height | |||||
Depth | |||||
Weights | |||||
Weight, approx. | 380 g |