CPU-blocks | |||
Number of blocks (total) | DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used | ||
OB | |||
● Number, max. | Limited only by RAM for code | ||
Data areas and their retentivity | |||
Retentive data area (incl. timers, counters, flags), max. | 14 kbyte | ||
Flag | |||
● Size, max. | 8 kbyte; Size of bit memory address area | ||
Local data | |||
● per priority class, max. | 16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB | ||
Address area | |||
Process image | |||
● Inputs, adjustable ● Outputs, adjustable |
1 kbyte 1 kbyte |
||
Hardware configuration | |||
Number of modules per system, max. | 3 comm. modules, 1 signal board, 8 signal modules | ||
Time of day | |||
Clock | |||
● Hardware clock (real-time) ● Backup time ● Deviation per day, max. |
Yes 480 h; Typical ±60 s/month at 25 °C |
||
Digital inputs | |||
Number of digital inputs ● of which inputs usable for technological functions |
14; Integrated 6; HSC (High Speed Counting) Yes |
||
Source/sink input | |||
Number of simultaneously controllable inputs | |||
all mounting positions | |||
— up to 40 °C, max. | 14 | ||
Input voltage | |||
● Rated value (DC) ● for signal “0” ● for signal “1” |
24 V 5 V DC at 1 mA 15 V DC at 2.5 mA |
||
Input delay (for rated value of input voltage) | |||
for standard inputs | |||
— parameterizable | 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in | ||
groups of four | |||
— at “0” to “1”, min. | 0.2 ms | ||
— at “0” to “1”, max. | 12.8 ms | ||
for interrupt inputs | |||
— parameterizable | Yes | ||
for technological functions | |||
— parameterizable | Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz | ||
Cable length | |||
● shielded, max. ● unshielded, max. |
500 m; 50 m for technological functions 300 m; for technological functions: No | ||
Digital outputs | |||
Number of digital outputs | 10; Relays | ||
Switching capacity of the outputs | |||
● with resistive load, max. ● on lamp load, max. |
2 A 30 W with DC, 200 W with AC |
||
Output delay with resistive load | |||
● “0” to “1”, max. ● “1” to “0”, max. |
10 ms; max. 10 ms; max. |
||
Relay outputs | |||
● Number of relay outputs ● Number of operating cycles, max. |
10 mechanically 10 million, at rated load voltage 100 000 |
||
Cable length | |||
● shielded, max. ● unshielded, max. |
500 m 150 m |
||
Analog inputs | |||
Number of analog inputs | 2 | ||
Input ranges | |||
● Voltage | Yes | ||
Input ranges (rated values), voltages | |||
● 0 to +10 V — Input resistance (0 to 10 V) |
Yes ≥100k ohms |
||
Cable length | |||
● shielded, max. | 100 m; twisted and shielded | ||
Analog outputs | |||
Number of analog outputs | 0 | ||
Analog value generation for the inputs | |||
Integration and conversion time/resolution per channel | |||
● Resolution with overrange (bit including sign), max. ● Integration time, parameterizable ● Conversion time (per channel) |
10 bit Yes 625 µs | ||
Encoder | |||
Connectable encoders | |||
● 2-wire sensor | Yes | ||
1. Interface | |||
Interface type | PROFINET | ||
Isolated | Yes | ||
automatic detection of transmission rate | Yes | ||
Autonegotiation | Yes | ||
Autocrossing | Yes | ||
Interface types | |||
● RJ 45 (Ethernet) ● Number of ports ● integrated switch |
Yes 1 No |
||
Protocols | |||
● PROFINET IO Controller | Yes | ||
● PROFINET IO Device | Yes | ||
● SIMATIC communication | Yes | ||
● Open IE communication | Yes; Optionally also encrypted | ||
● Web server | Yes | ||
● Media redundancy | No | ||
PROFINET IO Controller | |||
● Transmission rate, max. | 100 Mbit/s | ||
Services | |||
— PG/OP communication | Yes; encryption with TLS V1.3 pre-selected | ||
— Isochronous mode | No | ||
— IRT | No | ||
— PROFIenergy | No | ||
— Prioritized startup | Yes | ||
— Number of IO devices with prioritized startup, max. | 16 | ||
— Number of connectable IO Devices, max. | 16 | ||
— Number of connectable IO Devices for RT, max. | 16 | ||
— of which in line, max. | 16 | ||
— Activation/deactivation of IO Devices | Yes | ||
— Number of IO Devices that can be simultaneously | 8 | ||
activated/deactivated, max. | |||
— Updating time | The minimum value of the update time also depends on the communication | ||
component set for PROFINET IO, on the number of IO devices and the quantity | |||
of configured user data. | |||
PROFINET IO Device | |||
Services | |||
— PG/OP communication — Isochronous mode |
Yes; encryption with TLS V1.3 pre-selected No | ||
— IRT — PROFIenergy — Shared device — Number of IO Controllers with shared device, max. |
No
Yes Yes |
||
Protocols | |||
Supports protocol for PROFINET IO | Yes | ||
PROFIsafe | No | ||
PROFIBUS | Yes; CM 1243-5 (master) or CM 1242-5 (slave) required | ||
OPC UA | Yes; OPC UA Server | ||
AS-Interface | Yes; CM 1243-2 required | ||
Protocols (Ethernet) | |||
● TCP/IP | Yes | ||
● DHCP | No | ||
● SNMP | Yes | ||
● DCP | Yes | ||
● LLDP | Yes | ||
Redundancy mode | |||
Media redundancy | |||
— MRP — MRPD |
No
No |
||
SIMATIC communication | |||
● S7 routing | Yes | ||
Open IE communication | |||
● TCP/IP | Yes | ||
— Data length, max. | 8 kbyte | ||
● ISO-on-TCP (RFC1006) | Yes | ||
— Data length, max. | 8 kbyte | ||
● UDP | Yes | ||
— Data length, max. | 1 472 byte | ||
Web server | |||
● supported ● User-defined websites |
Yes Yes |
||
OPC UA | |||
● Runtime license required | Yes; “Basic” license required | ||
● OPC UA Server | Yes; data access (read, write, subscribe), method call, runtime license required | ||
— Application authentication | Available security policies: None, Basic128Rsa15, Basic256Rsa15, | ||
Basic256Sha256 | |||
— User authentication | “anonymous” or by user name & password | ||
— Number of sessions, max. | 10 | ||
— Number of subscriptions per session, max. | 5 | ||
— Sampling interval, min. | 100 ms | ||
— Publishing interval, min. | 200 ms | ||
— Number of server methods, max. | 20 | ||
— Number of monitored items, recommended max. | 1 000 | ||
— Number of server interfaces, max. | 2 | ||
— Number of nodes for user-defined server interfaces, | 2 000 | ||
max. | |||
Further protocols | |||
● MODBUS | Yes | ||
communication functions / header | |||
S7 communication | |||
● supported | Yes | ||
● as server | Yes | ||
● as client | Yes | ||
● User data per job, max. | See online help (S7 communication, user data size) | ||
Number of connections | |||
● overall | PG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved / 10 max; Total Connections: 34 reserved / 64 max |
||
Test commissioning functions | |||
Status/control | |||
● Status/control variable ● Variables |
Yes Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
||
Forcing | |||
● Forcing | Yes | ||
Diagnostic buffer | |||
● present | Yes | ||
Traces | |||
● Number of configurable Traces ● Memory size per trace, max. |
2 512 kbyte |
||
Interrupts/diagnostics/status information | |||
Diagnostics indication LED | |||
● RUN/STOP LED ● ERROR LED ● MAINT LED |
Yes
Yes |
||
Integrated Functions | |||
Counter ● Number of counters ● Counting frequency, max. |
6 100 kHz Yes Yes 8 Up to 4 with SB 1222 Yes 4 |
||
Frequency measurement | |||
controlled positioning | |||
Number of position-controlled positioning axes, max. | |||
Number of positioning axes via pulse-direction interface | |||
PID controller | |||
Number of alarm inputs | |||
Potential separation | |||
Potential separation digital inputs | |||
● Potential separation digital inputs ● between the channels, in groups of |
500V AC for 1 minute 1 |
||
Potential separation digital outputs | |||
● Potential separation digital outputs ● between the channels ● between the channels, in groups of |
Relays No 2 |
||
EMC | |||
Interference immunity against discharge of static electricity | |||
● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 — Test voltage at air discharge — Test voltage at contact discharge |
Yes 8 kV 6 kV |
||
Interference immunity to cable-borne interference | |||
● Interference immunity on supply lines acc. to IEC 61000- 4-4 ● Interference immunity on signal cables acc. to IEC 61000- 4-4 |
Yes Yes |
||
Interference immunity against voltage surge | |||
● Interference immunity on supply lines acc. to IEC 61000- 4-5 | Yes | ||
Interference immunity against conducted variable disturbance induced by high-frequency fields | |||
● Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 | Yes | ||
Emission of radio interference acc. to EN 55 011 | |||
● Limit class A, for use in industrial areas ● Limit class B, for use in residential areas |
Yes; Group 1 Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 |
||
Degree and class of protection | |||
IP degree of protection | IP20 | ||
Standards, approvals, certificates | |||
CE mark | Yes
Yes Yes Yes Yes |
||
UL approval | |||
cULus | |||
FM approval | |||
RCM (formerly C-TICK) | |||
KC approval | |||
Marine approval | Yes | ||
Ambient conditions | |||
Free fall | |||
● Fall height, max. | 0.3 m; five times, in product package | ||
Ambient temperature during operation | |||
● min. ● max. ● horizontal installation, min. ● horizontal installation, max. ● vertical installation, min. ● vertical installation, max. |
-20 °C 60 °C; Number of simultaneously activated inputs or outputs 7 or 5 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 14 or 10 at 55 °C horizontal or 45 °C vertical -20 °C 60 °C -20 °C 50 °C |
||
Ambient temperature during storage/transportation | |||
● min. ● max. |
-40 °C 70 °C |
||
Air pressure acc. to IEC 60068-2-13 | |||
● Operation, min. ● Operation, max. ● Storage/transport, min. ● Storage/transport, max. |
795 hPa 1 080 hPa 660 hPa 1 080 hPa |
||
Altitude during operation relating to sea level | |||
● Installation altitude, min. ● Installation altitude, max. |
-1 000 m 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
||
Relative humidity | |||
● Operation, max. | 95 %; no condensation | ||
Vibrations | |||
● Vibration resistance during operation acc. to IEC 60068- 2-6 ● Operation, tested according to IEC 60068-2-6 |
2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail Yes |
||
Shock testing | |||
● tested according to IEC 60068-2-27 | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms | ||
Pollutant concentrations | |||
● SO2 at RH < 60% without condensation | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free | ||
configuration / header | |||
configuration / programming / header | |||
Programming language | |||
— LAD — FBD — SCL |
Yes
Yes Yes |
||
Know-how protection | |||
● User program protection/password protection ● Copy protection ● Block protection |
Yes
Yes Yes |
||
Access protection | |||
● protection of confidential configuration data ● Protection level: Write protection ● Protection level: Read/write protection ● Protection level: Complete protection |
Yes
Yes Yes Yes |
||
programming / cycle time monitoring / header | |||
● adjustable | Yes | ||
Dimensions | |||
Width | 110 mm 100 mm 75 mm |
||
Height | |||
Depth | |||
Weights | |||
Weight, approx. | 435 g |