CPU-blocks | |||||||
Number of blocks (total) | DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used | ||||||
OB | |||||||
● Number, max. | Limited only by RAM for code | ||||||
Data areas and their retentivity | |||||||
Retentive data area (incl. timers, counters, flags), max. | 14 kbyte | ||||||
Flag | |||||||
● Size, max. | 4 kbyte; Size of bit memory address area | ||||||
Local data | |||||||
● per priority class, max. | 16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB | ||||||
Address area | |||||||
Process image | |||||||
● Inputs, adjustable ● Outputs, adjustable |
1 kbyte 1 kbyte |
||||||
Hardware configuration | |||||||
Number of modules per system, max. | 3 communication modules, 1 signal board | ||||||
Time of day | |||||||
Clock | |||||||
● Hardware clock (real-time) ● Backup time ● Deviation per day, max. |
Yes 480 h; Typical ±60 s/month at 25 °C |
||||||
Digital inputs | |||||||
Number of digital inputs ● of which inputs usable for technological functions |
6; Integrated 6; HSC (High Speed Counting) Yes |
||||||
Source/sink input | |||||||
Number of simultaneously controllable inputs | |||||||
all mounting positions | |||||||
— up to 40 °C, max. | 6 | ||||||
Input voltage | |||||||
● Rated value (DC) ● for signal “0” ● for signal “1” |
24 V 5 V DC at 1 mA 15 V DC at 2.5 mA |
||||||
Input current | |||||||
● for signal “1”, typ. | 4 mA; nominal | ||||||
Input delay (for rated value of input voltage) | |||||||
for standard inputs | |||||||
— parameterizable | 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 0.4 / | ||||||
0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 ms | |||||||
— at “0” to “1”, min. | 0.2 ms | ||||||
— at “0” to “1”, max. | 12.8 ms | ||||||
for interrupt inputs | |||||||
— parameterizable | Yes | ||||||
for technological functions | |||||||
— parameterizable | Single phase : 3 @ 100 kHz, differential: 3 @ 80 kHz | ||||||
Cable length | |||||||
● shielded, max. ● unshielded, max. |
500 m; 50 m for technological functions 300 m; for technological functions: No | ||||||
Digital outputs | |||||||
Number of digital outputs | 4 | ||||||
● of which high-speed outputs | 4; 100 kHz Pulse Train Output | ||||||
Limitation of inductive shutdown voltage to | L+ (-48 V) | ||||||
Switching capacity of the outputs | |||||||
● with resistive load, max. | 0.5 A | ||||||
● on lamp load, max. | 5 W | ||||||
Output voltage | |||||||
|
0.1 V; with 10 kOhm load 20 V |
||||||
Output current | |||||||
● for signal “1” rated value ● for signal “0” residual current, max. |
0.5 A 0.1 mA |
||||||
Output delay with resistive load | |||||||
● “0” to “1”, max. ● “1” to “0”, max. |
1 µs 5 µs |
||||||
Switching frequency | |||||||
● of the pulse outputs, with resistive load, max. | 100 kHz | ||||||
Relay outputs | |||||||
● Number of relay outputs | 0 | ||||||
Cable length | |||||||
● shielded, max. ● unshielded, max. |
500 m 150 m |
||||||
Analog inputs | |||||||
Number of analog inputs | 2 | ||||||
Input ranges | |||||||
● Voltage | Yes | ||||||
Input ranges (rated values), voltages | |||||||
● 0 to +10 V — Input resistance (0 to 10 V) |
Yes ≥100k ohms |
||||||
Cable length | |||||||
● shielded, max. | 100 m; twisted and shielded | ||||||
Analog outputs | |||||||
Number of analog outputs | 0 | ||||||
Analog value generation for the inputs | |||||||
Integration and conversion time/resolution per channel | |||||||
● Resolution with overrange (bit including sign), max. ● Integration time, parameterizable ● Conversion time (per channel) |
10 bit Yes 625 µs |
||||||
Encoder | |||||||
Connectable encoders | |||||||
● 2-wire sensor | Yes | ||||||
1. Interface | |||||||
Interface type | PROFINET Yes Yes Yes Yes |
||||||
Isolated | |||||||
automatic detection of transmission rate | |||||||
Autonegotiation | |||||||
Autocrossing | |||||||
Interface types | |||||||
● RJ 45 (Ethernet) ● Number of ports ● integrated switch |
Yes 1 No |
||||||
Protocols | |||||||
● PROFINET IO Controller ● PROFINET IO Device ● SIMATIC communication ● Open IE communication ● Web server ● Media redundancy |
Yes Yes Yes Yes; Optionally also encrypted Yes No |
||||||
PROFINET IO Controller | |||||||
● Transmission rate, max. | 100 Mbit/s | ||||||
Services | |||||||
— PG/OP communication — Isochronous mode — IRT — PROFIenergy — Prioritized startup — Number of IO devices with prioritized startup, max. — Number of connectable IO Devices, max. — Number of connectable IO Devices for RT, max. |
Yes; encryption with TLS V1.3 pre-selected No No No Yes 16 16 16 |
||||||
— of which in line, max. — Activation/deactivation of IO Devices — Number of IO Devices that can be simultaneously activated/deactivated, max. — Updating time |
16 Yes 8 The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data. |
||||||
PROFINET IO Device | |||||||
Services | |||||||
— PG/OP communication — Isochronous mode — IRT — PROFIenergy — Shared device — Number of IO Controllers with shared device, max. |
Yes; encryption with TLS V1.3 pre-selected No No Yes Yes 2 |
||||||
Protocols | |||||||
Supports protocol for PROFINET IO | Yes No Yes; CM 1243-5 (master) or CM 1242-5 (slave) required Yes; OPC UA Server Yes; CM 1243-2 required |
||||||
PROFIsafe | |||||||
PROFIBUS | |||||||
OPC UA | |||||||
AS-Interface | |||||||
Protocols (Ethernet) | |||||||
● TCP/IP ● DHCP ● SNMP ● DCP ● LLDP |
Yes No Yes Yes Yes | ||||||
Redundancy mode | |||||||
Media redundancy | |||||||
— MRP — MRPD |
No No | ||||||
SIMATIC communication | |||||||
● S7 routing | Yes | ||||||
Open IE communication | |||||||
● TCP/IP — Data length, max. — several passive connections per port, supported ● ISO-on-TCP (RFC1006) — Data length, max. ● UDP — Data length, max. |
Yes 8 kbyte Yes Yes 8 kbyte Yes 1 472 byte |
||||||
Web server | |||||||
● supported ● User-defined websites |
Yes Yes | ||||||
OPC UA | |||||||
● Runtime license required ● OPC UA Server — Application authentication — User authentication — Number of sessions, max. — Number of subscriptions per session, max. — Sampling interval, min. — Publishing interval, min. — Number of server methods, max. — Number of monitored items, recommended max. — Number of server interfaces, max. — Number of nodes for user-defined server interfaces, max. |
Yes; “Basic” license required Yes; Data access (read, write, subscribe), runtime license required Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 “anonymous” or by user name & password 10 5 100 ms 200 ms 20 1 000 2 2 000 |
||||||
Further protocols | |||||||
● MODBUS | Yes | ||||||
communication functions / header | |||||||
S7 communication | |||||||
● supported ● as server ● as client ● User data per job, max. |
Yes Yes Yes See online help (S7 communication, user data size) |
||||||
Number of connections | |||||||
● overall | PG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved / 10 max; Total Connections: 34 reserved / 64 max |
||||||
Test commissioning functions | |||||||
Status/control | |||||||
● Status/control variable ● Variables |
Yes Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
||||||
Forcing | |||||||
● Forcing | Yes | ||||||
Diagnostic buffer | |||||||
● present | Yes | ||||||
Traces | |||||||
● Number of configurable Traces ● Memory size per trace, max. |
2 512 kbyte |
||||||
Interrupts/diagnostics/status information | |||||||
Diagnostics indication LED | |||||||
● RUN/STOP LED ● ERROR LED ● MAINT LED |
Yes Yes Yes |
||||||
Integrated Functions | |||||||
Counter ● Number of counters ● Counting frequency, max. |
6 100 kHz Yes Yes 8 4; With integrated outputs Yes 4 4 100 kHz |
||||||
Frequency measurement | |||||||
controlled positioning | |||||||
Number of position-controlled positioning axes, max. | |||||||
Number of positioning axes via pulse-direction interface | |||||||
PID controller | |||||||
Number of alarm inputs | |||||||
Number of pulse outputs | |||||||
Limit frequency (pulse) | |||||||
Potential separation | |||||||
Potential separation digital inputs | |||||||
● Potential separation digital inputs ● between the channels, in groups of |
No 1 | ||||||
Potential separation digital outputs | |||||||
● Potential separation digital outputs ● between the channels ● between the channels, in groups of |
Yes No 1 |
||||||
EMC | |||||||
Interference immunity against discharge of static electricity | |||||||
● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 — Test voltage at air discharge — Test voltage at contact discharge |
Yes 8 kV 6 kV |
||||||
Interference immunity to cable-borne interference | |||||||
● Interference immunity on supply lines acc. to IEC 61000- 4-4 ● Interference immunity on signal cables acc. to IEC 61000- 4-4 |
Yes Yes |
||||||
Interference immunity against voltage surge | |||||||
● Interference immunity on supply lines acc. to IEC 61000- 4-5 | Yes | ||||||
Interference immunity against conducted variable disturbance induced by high-frequency fields | |||||||
● Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 | Yes | ||||||
Emission of radio interference acc. to EN 55 011 | |||||||
● Limit class A, for use in industrial areas ● Limit class B, for use in residential areas |
Yes; Group 1 Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 |
||||||
Degree and class of protection | |||||||
IP degree of protection | IP20 | ||||||
Standards, approvals, certificates | |||||||
CE mark | Yes Yes Yes Yes Yes Yes Yes |
||||||
UL approval | |||||||
cULus | |||||||
FM approval | |||||||
RCM (formerly C-TICK) | |||||||
KC approval | |||||||
Marine approval | |||||||
Ambient conditions | |||||||
Free fall | |||||||
● Fall height, max. | 0.3 m; five times, in product package | ||||||
Ambient temperature during operation | |||||||
● min. ● max. ● horizontal installation, min. ● horizontal installation, max. ● vertical installation, min. ● vertical installation, max. |
-20 °C 60 °C -20 °C 60 °C -20 °C 50 °C |
||||||
Ambient temperature during storage/transportation | |||||||
● min. ● max. |
-40 °C 70 °C |
||||||
Air pressure acc. to IEC 60068-2-13 | |||||||
● Operation, min. ● Operation, max. ● Storage/transport, min. ● Storage/transport, max. |
795 hPa 1 080 hPa 660 hPa 1 080 hPa |
||||||
Altitude during operation relating to sea level | |||||||
● Installation altitude, min. ● Installation altitude, max. |
-1 000 m 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
||||||
Relative humidity | |||||||
● Operation, max. | 95 %; no condensation | ||||||
Vibrations | |||||||
● Vibration resistance during operation acc. to IEC 60068- 2-6 ● Operation, tested according to IEC 60068-2-6 |
2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail Yes |
||||||
Shock testing | |||||||
● tested according to IEC 60068-2-27 | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms | ||||||
Pollutant concentrations | |||||||
● SO2 at RH < 60% without condensation | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free | ||||||
configuration / header | |||||||
configuration / programming / header | |||||||
Programming language | |||||||
— LAD — FBD — SCL |
Yes Yes Yes |
||||||
Know-how protection | |||||||
● User program protection/password protection ● Copy protection ● Block protection |
Yes Yes Yes | ||||||
Access protection | |||||||
● protection of confidential configuration data ● Protection level: Write protection ● Protection level: Read/write protection ● Protection level: Complete protection |
Yes Yes Yes Yes |
||||||
programming / cycle time monitoring / header | |||||||
● adjustable | Yes | ||||||
Dimensions | |||||||
Width | 90 mm 100 mm 75 mm |
||||||
Height | |||||||
Depth | |||||||
Weights | |||||||
Weight, approx. | 370 g |
SIEMENS- 6ES7211-1AE40-0XB0
SIMATIC S7-1200, CPU 1211C, compact CPU, DC/DC/DC, onboard I/O: 6 DI 24 V DC; 4 DO 24 V DC; 2 AI 0-10 V DC, Power supply: DC 20.4-28.8V DC,
Program/data memory 50 KB
Category: Automation & Instrumentation
Description
Additional information
Dimensions | 90 × 100 × 75 cm |
---|---|
Product type designation |
CPU 1211C DC/DC/DC |
Firmware version |
V4.5 |
Programming package |
STEP 7 V17 or higher |
Rated value (DC) ● 24 V DC |
yes |
permissible range, lower limit (DC) |
20.4 V |
Reverse polarity protection |
yes |
Load voltage/Rated value (DC) |
24 V |
Load voltage/permissible range, lower limit (DC) |
20.4 V |
Load voltage L+/ |
28.8 V |
Current consumption, max |
900 mA; CPU with all expansion modules |
Inrush current, max. |
12 A; at 28.8 V DC |
I²t |
0.5 A²·s |
for backplane bus (5 V DC), max |
750 mA; Max. 5 V DC for CM |
24 V encoder supply |
L+ minus 4 V DC min. |
Power loss, typ |
8 W |
Work memory / integrated |
50 kbyte |
Load memory / integrated |
1 Mbyte |
Backup / present |
yes |
Backup / maintenance-free |
yes |
Backup / without battery |
yes |
for bit operations, typ |
0.08 µs; / instruction |
for floating point arithmetic |
2.3 µs; / instruction |
Brand |
SIEMENS |
Reviews (0)
Be the first to review “SIEMENS- 6ES7211-1AE40-0XB0” Cancel reply
Shipping & Delivery
Reviews
There are no reviews yet.